• Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
  • Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
  • Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
  • Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
  • Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
  • Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer

Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer

After-sales Service: Longtime
Warranty: 2years
Type: Induction Moisture Meter
Samples:
US$ 30000/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer pictures & photos
Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
US $36,869 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • One-stop Shopping
  • Certifications
  • Packaging & Shipping
  • Exhibition
Overview

Basic Info.

Model NO.
ICP6800
Analysis Method
Chemical Analysis
Display
Standard
Application
All
Portable
Non-portable
Physical Analysis Type
Suitable
Chemical Analysis Type
Toluene Method
Operating Mode
Touch Screen
Heating Mode
Standard Heating
Off Mode
Automatic
Transport Package
Carton
Specification
1800*800*850mm
Trademark
Macylab
Origin
China
HS Code
9027300000
Production Capacity
5000PCS/Month

Packaging & Delivery

Package Size
126.00cm * 75.00cm * 90.00cm
Package Gross Weight
120.000kg

Product Description

Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)


Application Field
Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

Application Environment
CONTENT                                                   RANGE
Shipping/Storage Ambient Temperature         15ºC-25ºC
Shipping/Storage Relative Humidity               70%
Atmospheric pressure                                  86-106 kPa
Power Supply                                              220±10V  50-60MHz
Working Humidity                                        70%
Working Temperature                                  15ºC-30ºC
 
RFPower technical parameter:
Circuit type: solid-state RF power supply, with function of automatch
Frequency: 27.12MHz±0.05%
Frequency Stability: <0.1%
Power Output: 800W-1200W
Power Output Stability: <0.3%
Escaped RF radiation: 30cm away from the instrument, electric field: E<2V/m
 
Sampling System Technical Parameter:
Output working coil inner diameter :25mm
Torque tube: Three concentric, external diameter 20mm
Coaxial nebulizer:Outer diameter 6mm
Double barrel atomizing chamber: Outer diameter 34mm
 
Gas Flow Controls
1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)
2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)
3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)
4.Pressure Maintaining Valve(0-0.4MPa)
5.Cooling Water:Temperature: 20-25ºC, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa
 
Spectrometer
Optics:Czerny-Turner type
Focal length: 1000 mm
Grating: Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm
Reciprocal linear dispersion: 0.26nm/mm
Resolution: 0.007nm (3600 line grating);≤0.015nm (2400line grating)
Wavelength range: 3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nm
Minimum pace of stepping motor: 0.0006 nm
Exit Slit:12μm;Entrance Slit:10μm
 
Photoelectric Converter Performance
Photomultiplier tube specification: R293/R928
Negative HV on PMT: 0-1000V;Stability: <0.05%
 
Overall Performance
Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)
Repeatability: RSD(Relative Standard Deviation)1.5%
Stability: RSD(Relative Standard Deviation) 2%
Detection Limits (µg/L):
Element WL(nm) Limit   Element WL(nm) Limit

La

408.672 

<3.0
 
Cr      
267.716  <5.0    
Ce 413.765  
<5.0
 
Al        

396.152  
<5.0      
Pr
414.311 

<5.0
 
Zr       

343.823  

<5.0     

Nd
401.225  <5.0  
Ag      
328.068   <3.0     
Sm 360.946  
<10.0
 
Sr     

407.771  
<1.0     

Eu

381.967 

<1.0
  Au     
242.795 
<5.0    

Gd

342.247 
<10.0   Pt    265.945   
<5.0

Tb

350.917   

<3.0
 
Pd     

340.458 
<5.0    
Dy 353.170  <3.0  
Ir       

224.268  
<10.0    
Ho
345.600   

<3.0
 
Rh      
343.489  
<10.0    

Er

337.271  

<3.0
 
Ru       

240.272  

<5.0     
Tm
313.126 

<3.0
  Ba    
455.403   

<1.0   
Yb
369.419 

<1.0
  As     
228.812  
15      

Lu
261.541  <3.0  
Sb       
206.833   15     
Y 371.030  <1.0  
Bi       
223.061   10    
Sc 335.373   
<1.0
 
Hg      
253.652  
15    
Ta
226.230 
<5.0  
Pb       
220.353   15     

Nb
313.340 
<5.0
  Ga        294.364    10     
Mn
257.610 

<3.0
 
Se    
203.985    10

Mg

279.553 

<1.0
  Sn      
242.949  
20    

B

249.773 

<10.0
 
Te       
214.281  
10     
Zn 213.856  <3.0  
Ta      
226.230   5.0    

Co
228.616 
<3.0
  Th         283.730   
10     
Si
251.611   
<10.0  
Tl       
276.787    30      

Ni

232.003 
<5.0   Re       227.525   5      

Cd

226.502 
<3.0   Ge   
209.426    
15

Fe
239.562  
<3.0
 
Os        
225.585    1       

Ca

393.366  

<1.0
 
W        
207.911    10     

Mo

281.615  
<5.0   Cu
324.754 

<3.0
V 310.230   <5.0  
Li        
670.784   
3       

Be
313.041  <1.0   Na         588.995     20      
Ti
334.941   
<3.0  
K

766.490
60
One-stop Shopping

 

Icp 6800 Oes Inductively Coupled Plasma Optical Emission SpectrometerIcp 6800 Oes Inductively Coupled Plasma Optical Emission SpectrometerIcp 6800 Oes Inductively Coupled Plasma Optical Emission SpectrometerIcp 6800 Oes Inductively Coupled Plasma Optical Emission SpectrometerIcp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
Certifications

 


Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
Packaging & Shipping
 

 

Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
Exhibition

 

Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer pictures & photos
Icp 6800 Oes Inductively Coupled Plasma Optical Emission Spectrometer
US $36,869 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP