• Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
  • Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
  • Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
  • Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
  • Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
  • Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer

Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer

After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Warranty: > 1Year
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer pictures & photos
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
US $38,304-41,786 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Certifications
  • Exhibition
  • One-stop Shoping
  • FAQ
Overview

Basic Info.

Model NO.
ICP-6800S
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
for Petrochemical Detection
27.12MHz
Power Output
800 W ~1500 W
Power
220V, 30A
Stability
Rsd≤2%
Transport Package
Wood
Specification
1630*700*830mm
Trademark
Macylab
Origin
Shanghai
HS Code
9027300000
Production Capacity
10000

Packaging & Delivery

Package Size
18.00cm * 8.00cm * 0.08cm
Package Gross Weight
350.000kg

Product Description



 

Product Description

 

Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer

ICP-6800S Inductively Coupled Plasma Emission Spectrometer for Petrochemical
 

ICP6800S is a high-tech product. Its full name is single-channel scanning Inductively Coupled Plasma
emission spectrometer. It is mainly used in rare earth industry, silicon industry, petrochemical industry,
ore analysis, metal smelting, geological research, drug safety, experimental research, environmental
testing and other fields.
 
Product Parameters

 

RF Generator
1) Circuit type: solid-state RF power supply, with function of automatch.
2) Frequency: 27.12MHz
3) Power Output: 800 W ~1500 W
4) Escaped RF radiation: 30cm away from the instrument, electric field: E<10V/m;magnetic field:
H<0.2A/m
5) Power: 220V, 30A
6)Gas Flow controls:
Plasma Argon Flowmeter: (60~1200) L/h or (1~20)L/min
Auxiliary Argon Flowmeter: (3~60) L/h or (0.05~1.0) L/min
Carrier Argon Flowmeter:(
3~60)L/h or (0.05~1.0) L/min
7)Cooling Water: temperature range 20ºC~25ºC, resistivity>1 MΩ.

 
Spectrometer
1) Optics: Czerny turner type
2) Resolution:
≤0.015nm (2400 wire grating)
≤ 0.008nm (3600 wire grating)
≤ 0.005nm (4320 wire grating)
3) Wavelength range:
2400 wire grating: (190nm~800) nm
3600 wire grating: (190nm~500) nm
4320 wire grating: (190nm~460) nm

 
Electronics Measurement and Control Circuit
1) Photomultiplier tube specification: Hamamatsu PMT
2) Communication circuit: Ethernet interface
 
Computer System
1) A set of major brand computer, which fit for XP, WIN7,WIN10 operating system
2) Printer: Brand printer
 

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

 

Element WL(nm) Limit   Element WL(nm) Limit
La 408.672 <3.0   Cr 267.716 <5.0
Ce 413.765 <5.0   Al 396.152 <5.0
Pr 414.311 <5.0   Zr 343.823 <5.0
Nd 401.225 <5.0   Ag 328.068 <3.0
Sm 360.946 <10.0   Sr 407.771 <1.0
Eu 381.967 <1.0   Au 242.795 <5.0
Gd 342.247 <10.0   Pt 265.945 <5.0
Tb 350.917 <3.0   Pd 340.458 <5.0
Dy 353.170 <3.0   Ir 224.268 <10.0
Ho 345.600 <3.0   Rh 343.489 <10.0
Er 337.271 <3.0   Ru 240.272 <5.0
Tm 313.126 <3.0   Ba 455.403 <1.0
Yb 369.419 <1.0   As 228.812 ≤15
Lu 261.541 <3.0   Sb 206.833 ≤15
Y 371.030 <1.0   Bi 223.061 ≤10
Sc 335.373 <1.0   Hg 253.652 ≤15
Ta 226.230 <5.0   Pb 220.353 ≤15
Nb 313.340 <5.0   Ga 294.364 ≤10
Mn 257.610 <3.0   Se 203.985 ≤10
Mg 279.553 <1.0   Sn 242.949 ≤20
B 249.773 <10.0   Te 214.281 ≤10
Zn 213.856 <3.0   Ta 226.230 ≤5.0
Co 228.616 <3.0   Th 283.730 ≤10
Si 251.611 <10.0   Tl 276.787 ≤30
Ni 232.003 <5.0   Re 227.525 ≤5
Cd 226.502 <3.0   Ge 209.426 ≤15
Fe 239.562 <3.0   Os 225.585 ≤1
Ca 393.366 <1.0   W 207.911 ≤10
Mo 281.615 <5.0   Cu 324.754 <3.0
V 310.230 <5.0   Li 670.784 ≤3
Be 313.041 <1.0   Na 588.995 ≤20
Ti 334.941 <3.0   K 766.490 ≤60
Company Profile

 

Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometer


 

Certifications

 

Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer

 

Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer

 

 

Exhibition

 

Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer


 

 

 

One-stop Shoping

 

Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer

 

 

 

 

FAQ

 

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.

 

 

 

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer pictures & photos
Determination of Heavy Metals in Petrochemical Inductively Coupled Plasma Emission Spectrometer
US $38,304-41,786 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP