• for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
  • for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
  • for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
  • for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
  • for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
  • for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer

for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer

After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Warranty: 1 Year
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer pictures & photos
for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
US $8,600-9,500 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Product Description
  • Certifications
  • Application
  • Technical parameters
  • Competitive Advantages
  • The Company
  • R&D
Overview

Basic Info.

Model NO.
AA-1800C
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Non-Customized
Product Name
AA-1800c
Key Words
Single Flame
Spectral Bandwidth
0.1,0.2,0.4,,1.0,2.0nm (Automatic Adjustable)
Grating
1800/mm
Transport Package
Carton
Specification
360*
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
50PCS/Month

Packaging & Delivery

Package Size
126.00cm * 64.00cm * 71.00cm
Package Gross Weight
120.000kg

Product Description

for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometerfor Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometerfor Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometerfor Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometerfor Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
Product Description

 

AA-1800C atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.

Images:
 
Detailed Product Description

 

Product Name: Photometer Source Type: Hollow Cathode Lamps
Wavelength Range: 190~900nm Spectral Bandwidth: 0/0.2/0.4/1.0/2.0nm
Wavelength Accuracy: ≤0.15nm
High Light:

AA-1800C atomic absorption spectrophotometer

scientific research atomic absorption spectrophotometer

220v flame atomic spectroscopy

Certifications

 

 

for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
 
Application

 

AA-1800C atomic absorption spectrophotometer is now widely used in scientific research,quality control,disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples,equipment maintenance, simple and convenient.

Technical parameters

 

Mainframe
Model: AA-1800C
Light Source: ≤6 lamps automatic turret, automatic alignment
Power Supply: 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current: pulsed power supply
Optical System: large 1800 /mm grating ruling, full closed optical system
Wavelength Range: 180nm-900nm                  
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy: ≤0.15nm
Wavelength Repeatability: ±0.1nm
Spectral Bandwidth: 0nm,0.2nm,0.4nm,1.0nm,2.0nm
(5 steps with automatic changeover)
Baseline Stability: ≤±0.002A/30 min (Static)      
≤±0.005A/30min (Dynamic)
Absorbance Range: 0-4A
Detector: imported photomultiplier tube 
Flame Analytical System
Burner Head: full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber: polymer explosion-proof spray chamber
Nebulizer: atomizer efficient glass atomizer, can also be customized
Ignition Type: microcomputer control, automatic ignition
Gas Control: automatic gas control system
Detection Limits(Cu): 0.002μg/mL
Precision: RSD≤0.5%
Competitive Advantages

 


High precision automatic optical system
1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 6 socket configuration six independent lamp power supply, can be respectively preheating 
Polymer spray chamber
Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity and stability
Titanium burner
Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame
Automatic analysis
It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automaticwavelength scanning and searching peak
Software function
High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method
 
The Company

 


for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer

 
R&D

 

for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
 
 
Factory
for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
 
                                                  for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer     


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer pictures & photos
for Chemical Engineering Metal Analysis Six Lamps Atomatic Absorption Spectrometer
US $8,600-9,500 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP