Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
  • Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
  • Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
  • Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
  • Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
  • Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Exhibition
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
V-1200
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Product Name
Visible Spectrometer
Spectral Bandwidth
2nm
Wavelength Accuracy
±1.0nm
Stability
0.001A/H@500nm
Transport Package
Carton
Specification
460*330*210mm
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
1000PCS/Month

Packaging & Delivery

Package Size
60.00cm * 45.00cm * 32.00cm
Package Gross Weight
13.000kg

Product Description

Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
Product Description

Automatic wavelength adjustment
Single-chip microcomputer control, 128 * 64 LCD
Filter automatic switching
Huge memory space to store multiple sets of data and curves
With up to 10 standard sample for measurement function of standard curve establish
Standard curve parameters can be powered down to save the measurement setup
Spectrum scanning can be achieved through the PC software control is more precise and flexible measurement requirements (optional)
By direct input K, B factor to establish a standard curve for quantitative measurement
Master Standards can be directly input and the corresponding concentration values establish a standard curve for quantitative measurement
The large LCD monitor can display multiple sets of data
Large sample pool (5mm~100mm)
With USB Interface
Universal parallel interface, you can print the title bar, the measured data, curve parameters, curve standard sample points and curves
Automatic transfer 0, transfer 100% functional

 

Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
Visible spectrophotometer V-1200 model is a microprocessor controlled automatic type instrument, the hosts can complete the standard curve, concentration measurement and photometry functions

 

 
Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability
Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability


Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability

Company Profile

Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.

Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometer


Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability  
Exhibition

Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability



 
Certifications

Visible Spectrometer Determination of Grain Content in Vegetable Oil High Stability

FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier