• China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory
  • China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory
  • China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory
  • China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory
  • China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory

China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory

After-sales Service: 2years
Warranty: 1years
Element: Metals Analyzer
Samples:
US$ 42000/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory pictures & photos
China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory
US $42,000-55,500 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • One-stop Shopping
  • FAQ
Overview

Basic Info.

Model NO.
ICP-6800
Analysis
Photoelectric Colorimetry
Display
Computer Screen
Application
Metal
Frequency
50±0.5Hz
Performance
Automation
Function
Storage, Cleared
Weight
100-500Kg
Power Source
AC220V±22V
Customized
Customized
Atmospheric Pressure
86-106 Kpa
Power Supply
220±10V50-60MHz
Working Humidity
≤70%
Working Temperature
15ºC-30ºC
Transport Package
Carton
Specification
1800*800*850mm
Trademark
Macylab
Origin
China
HS Code
9027300000
Production Capacity
5000PCS/Month

Packaging & Delivery

Package Size
180.00cm * 80.00cm * 85.00cm
Package Gross Weight
350.000kg

Product Description

China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory

ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)
Application Field
Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

Application Environment
CONTENT                                                   RANGE 19932323279
Shipping/Storage Ambient Temperature         15ºC-25ºC
Shipping/Storage Relative Humidity               ≤70%
Atmospheric pressure                                  86-106 kPa
Power Supply                                              220±10V  50-60MHz
Working Humidity                                        ≤70%
Working Temperature                                  15ºC-30ºC
 
RFPower technical parameter:
Circuit type: solid-state RF power supply, with function of automatch
Frequency: 27.12MHz±0.05%
Frequency Stability: <0.1%
Power Output: 800W-1200W
Power Output Stability: <0.3%
Escaped RF radiation: 30cm away from the instrument, electric field: E<2V/m
 
Sampling System Technical Parameter:
Output working coil inner diameter :25mm
Torque tube: Three concentric, external diameter 20mm
Coaxial nebulizer:Outer diameter 6mm
Double barrel atomizing chamber: Outer diameter 34mm
 
Gas Flow Controls
1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)
2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)
3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)
4.Pressure Maintaining Valve(0-0.4MPa)
5.Cooling Water:Temperature: 20-25ºC, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa
 
Spectrometer
Optics:Czerny-Turner type
Focal length: 1000 mm
Grating: Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm
Reciprocal linear dispersion: 0.26nm/mm
Resolution:≤ 0.007nm (3600 line grating);≤0.015nm (2400line grating)
Wavelength range: 3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nm
Minimum pace of stepping motor: ≤0.0006 nm
Exit Slit:12μm;Entrance Slit:10μm
 
Photoelectric Converter Performance
Photomultiplier tube specification: R293/R928
Negative HV on PMT: 0-1000V;Stability: <0.05%
 
Overall Performance
Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)
Repeatability: RSD(Relative Standard Deviation)≤1.5%
Stability: RSD(Relative Standard Deviation) ≤2%
Detection Limits (µg/L):
 
Element WL(nm) Limit   Element WL(nm) Limit

La

408.672 

<3.0
 
Cr      
267.716  <5.0    
Ce 413.765  
<5.0
 
Al        

396.152  
<5.0      
Pr
414.311 

<5.0
 
Zr       

343.823  

<5.0     

Nd
401.225  <5.0  
Ag      
328.068   <3.0     
Sm 360.946  
<10.0
 
Sr     

407.771  
<1.0     

Eu

381.967 

<1.0
  Au     
242.795 
<5.0    

Gd

342.247 
<10.0   Pt    265.945   
<5.0

Tb

350.917   

<3.0
 
Pd     

340.458 
<5.0    
Dy 353.170  <3.0  
Ir       

224.268  
<10.0    
Ho
345.600   

<3.0
 
Rh      
343.489  
<10.0    

Er

337.271  

<3.0
 
Ru       

240.272  

<5.0     
Tm
313.126 

<3.0
  Ba    
455.403   

<1.0   
Yb
369.419 

<1.0
  As     
228.812  
15      

Lu
261.541  <3.0  
Sb       
206.833   15     
Y 371.030  <1.0  
Bi       
223.061   10    
Sc 335.373   
<1.0
 
Hg      
253.652  
15    
Ta
226.230 
<5.0  
Pb       
220.353   15     

Nb
313.340 
<5.0
  Ga        294.364    10     
Mn
257.610 

<3.0
 
Se    
203.985    10

Mg

279.553 

<1.0
  Sn      
242.949  
20    

B

249.773 

<10.0
 
Te       
214.281  
10     
Zn 213.856  <3.0  
Ta      
226.230   5.0    

Co
228.616 
<3.0
  Th         283.730   
10     
Si
251.611   
<10.0  
Tl       
276.787    30      

Ni

232.003 
<5.0   Re       227.525   5      

Cd

226.502 
<3.0   Ge   
209.426    
15

Fe
239.562  
<3.0
 
Os        
225.585    1       

Ca

393.366  

<1.0
 
W        
207.911    10     

Mo

281.615  
<5.0   Cu
324.754 

<3.0
V 310.230   <5.0  
Li        
670.784   
3       

Be
313.041  <1.0   Na         588.995     20      
Ti
334.941   
<3.0  
K

766.490
60


 

China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes FactoryChina Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes FactoryChina Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes FactoryChina Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory
Precision analysis
The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.


Quick test
In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.
Technical parameters of the instrument
Output power: 800 -1500W

Total argon consumption:≤14L/min
Wavelength range:160nm - 1000 nm
Resolution: < 0.0065nm@200nm
Instrument technical index
Method of observation: vertical observation
Liquid content:0.01ppm~thousands of ppm.
Solid content:0.001%~70%
Repeatability: RSD < 1%
Stability: RSD <1.5%(within 2 hours)
Element detection limit (μg/L): most elements 1ppb~10ppb

Application area

Silicon industry, metallurgical industry, water quality analysis, geology, ore analysis, petrochemical, medical, sanitary, agricultural environmental protection, commodity, food quality inspection.
.
China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes FactoryChina Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory
One-stop Shopping

China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes FactoryChina Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes FactoryChina Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes FactoryChina Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes FactoryChina Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory

FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory pictures & photos
China Inductively Coupled Plasma Optical Emission Spectrometer Icp-Oes Factory
US $42,000-55,500 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP