Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research
  • Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research
  • Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research
  • Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research
  • Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research
  • Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Main Features
  • Product Parameters
  • Exhibition
  • The Company
  • Our Factory
  • Competitive Advantages
Overview

Basic Info.

Model NO.
AA-1800DL
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Product Name
AA-1800dl
Optical System
High Precision Automatic Optical System
Detector
Import Photomultipiler Tube
Wavelength Range
185-900nm
Transport Package
Carton
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
50PCS/Month

Packaging & Delivery

Package Size
105.00cm * 70.00cm * 87.00cm
Package Gross Weight
128.800kg

Product Description


Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research 
Product Description
 

 

AA-1800DL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.
AA-1800DL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.
Detailed Photos

 

Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research

Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific ResearchMacy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific ResearchMacy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific ResearchMacy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific ResearchMacy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research
Main Features

 

High precision automatic optical system
1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 8 socket configuration 8 independent lamp power supply, can be respectively preheating
Polymer spray chamber
Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability
Titanium burner
Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame
Automatic analysis
It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic
adjustment of the power supply parameters and the beam
position, automaticwavelength scanning and searching peak
Software function
High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method
Product Parameters

 

Mainframe
Model : AA-1800DL
Light Source : ≤8 lamps automatic turret, automatic alignment
Power Supply : 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current : pulsed power supply
Optical System : large 1800 /mm grating ruling, full closed optical system
Wavelength Range : 185nm-900nm
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy : ±0.15nm
Wavelength Repeatability : <0.10nm
Spectral Bandwidth : 0.1,0.2,0.4,0.7,1.0,1.4,2.0nm
(7 steps with automatic changeover)
Baseline Stability : ≤±0.002A/30 min (Static)
≤±0.004A/30min (Dynamic)
Absorbance Range : 0-4A
Flame Analytical System
Detector : imported photomultiplier tube
Burner Head : full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber : polymer explosion-proof spray chamber
Nebulizer : atomizer efficient glass atomizer, can also be customized
Ignition Type : microcomputer control, automatic ignition
Gas Control : automatic gas control system
Detection Limits(Cu) : 0.002μg/mL
Precision : RSD≤0.5%


 

Exhibition

 


Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific ResearchMacy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research

The Company


Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research

 

 
 
Our Factory

 

Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research


 

Competitive Advantages

 

Quality
1. Our products have good quality and very positive reputations in the market.
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders.
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
 
 
Macy High Precision Automatic Optical System Atomic Absorption Spectrophotometer for Scientific Research
 
                                        

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier