Customization: | Available |
---|---|
After-sales Service: | Online Technical Support |
Application: | Industrial |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ICP-6810 |
ICP-6810 is a full-spectrum direct-reading inductively coupled plasma emission spectrometer for the determination of trace and trace elements in different substances (dissolved in nitric acid, hydrochloric acid, hydrofluoric acid, etc.).
It is widely used in environmental protection, petroleum products, rare earth, semiconductor, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.
Performance stability
The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.
Injection automation
Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.
Precision analysis
The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.
Quick test
In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.
Technical parameters of the instrument
Instrument technical index
RFPower technical parameter
ircuit type |
solid-state RF Power supply, with function of automatch |
Frequercy |
27.12MHz±0.05% |
Frequency Stablity |
<0.1% |
Power Output |
800W-1500W |
Power Output Stability |
<0.3% |
Escaped RF radiation |
30cm away from the instrument, electric fiekd: E<2V/m |
Sampling System Technical Parameter
Output working coil imer diameter |
25mm |
Torpue tube |
Three concentric, extemal diameter 20mm |
Coaxial nebulizer |
Outer dameter 6mm |
Double barrel atomizing chamber |
Outer diameter 34mm |
Gas Flow Controls
Plasma Argon Flowmeter |
(100-1000)L/h(1.6-16L/min) |
Auxiliary Argon Fiowmeter |
(100-1000)L/h(0.16-1.6L/min) |
Auxiliary Carrier Argon Flowmeter |
(100-1000)L/h(0.16-1.6L/min) |
Pressune Maintaining Value |
(0-0.4MPa) |
Cooling Water:Temperature |
20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa |
Technical index of spectrometer
Grating |
Midde step grating, 52.67 lp/mm, 64 sparkle angle |
Wavelength range |
160-1000 nm |
Numerical aperture |
F≤8, ultra-high luminous flux to ensure the detection limit and sensitivity of the instrument |
Resolution |
< 0.0065nm@200nm |
Astigmatism |
Equivalent background concentration of 10000 ppm Ca solution at As 189.042 nm <2 ppm |
Light chamber |
Precision constant temperature, 35±0.1ºC, Distributed nitrogen punging, normal purging 1.8L/min, fast purging 3.8L/min |
Testing device technical specifications
Detector |
CID |
Target Size |
27.6mm x27.6mm, 1024x1024 addressing detection units |
Reading mode |
Non-destructive read (NDRO, full reading (FF) and arbitrary read integral (RAI) |
Detection Limits (μg/L):
Element | WL(nm) | Limit | Element | WL(nm) | Limit | |
La | 408.672 | <3.0 | Cr | 267.716 | <5.0 | |
Ce | 413.765 | <5.0 | Al | 396.152 | <5.0 | |
Pr | 414.311 | <5.0 | Zr | 343.823 | <5.0 | |
Nd | 401.225 | <5.0 | Ag | 328.068 | <3.0 | |
Sm | 360.946 | <10.0 | Sr | 407.771 | <1.0 | |
Eu | 381.967 | <1.0 | Au | 242.795 | <5.0 | |
Gd | 342.247 | <10.0 | Pt | 265.945 | <5.0 | |
Tb | 350.917 | <3.0 | Pd | 340.458 | <5.0 | |
Dy | 353.170 | <3.0 | Ir | 224.268 | <10.0 | |
Ho | 345.600 | <3.0 | Rh | 343.489 | <10.0 | |
Er | 337.271 | <3.0 | Ru | 240.272 | <5.0 | |
Tm | 313.126 | <3.0 | Ba | 455.403 | <1.0 | |
Yb | 369.419 | <1.0 | As | 228.812 | ≤15 | |
Lu | 261.541 | <3.0 | Sb | 206.833 | ≤15 | |
Y | 371.030 | <1.0 | Bi | 223.061 | ≤10 | |
Sc | 335.373 | <1.0 | Hg | 253.652 | ≤15 | |
Ta | 226.230 | <5.0 | Pb | 220.353 | ≤15 | |
Nb | 313.340 | <5.0 | Ga | 294.364 | ≤10 | |
Mn | 257.610 | <3.0 | Se | 203.985 | ≤10 | |
Mg | 279.553 | <1.0 | Sn | 242.949 | ≤20 | |
B | 249.773 | <10.0 | Te | 214.281 | ≤10 | |
Zn | 213.856 | <3.0 | Ta | 226.230 | ≤5.0 | |
Co | 228.616 | <3.0 | Th | 283.730 | ≤10 | |
Si | 251.611 | <10.0 | Tl | 276.787 | ≤30 | |
Ni | 232.003 | <5.0 | Re | 227.525 | ≤5 | |
Cd | 226.502 | <3.0 | Ge | 209.426 | ≤15 | |
Fe | 239.562 | <3.0 | Os | 225.585 | ≤1 | |
Ca | 393.366 | <1.0 | W | 207.911 | ≤10 | |
Mo | 281.615 | <5.0 | Cu | 324.754 | <3.0 | |
V | 310.230 | <5.0 | Li | 670.784 | ≤3 | |
Be | 313.041 | <1.0 | Na | 588.995 | ≤20 | |
Ti | 334.941 | <3.0 | K | 766.490 | ≤60 |
Application Field |
Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.
Certificate |
Company Profile |
Exhibitions |
1. How to pick up the best among these models?
A:Tell us your request on product and almost target price,we recommend you the most suitable model. Selling you the most expensive product is not our goal,selling you the most suitable is!
2. How to place order or pay?
you can place order to us directly,we offer you PI (contract) with bank information, you pay here,we ship the product,Every process is based on PI.
3. How to transport the product?
A: Depending on the quantity and what kind of machine you order or whether you are urgent or not to check how big it is to check the freight.
By sea: More than 60kg or big quantity;Safe,cheap but slow;
Usually 11-30 days to North America;
30-45 days to Middle of South America;
40-60 days to South America;
15-28 days to South Africa;
25-33 days to Europe;
30-45 days to East Europe;
35-45 days to North Europe;
28-35 days to Mediterranean countries;
28-40 days to Middle East countries;
7-20 days to Southeast Asia countries;
By air to airport: Suit for big product or quantity but urgent a lot. Usually 7-10 days arrive. Some direct flight can arrive at 3-5 days.
By Express delivery such as DHL,FedEx,TNT: Suit for small or not too heavy and very urgent product. Generally 5-7 days arrive.
4. What kind of warranty will be offer?
A: Most of our product we offer 1 years warranty,except perishable part. During the warranty time,any problem,we offer after-sale service; Welcome our customer talk this with our sales directly,they will offer you more details;
5. How's our service?
A: Before place order,any inquiry we make sure will reply in 1 day,and offer you our suitable advice based on our professional product knowledge;
After place order,we will help you follow the shipping information until you get these machines;
If any problems on delivery or using,we make sure you can contact us in 1 day.