Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
  • Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
  • Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
  • Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
  • Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
  • Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
Find Similar Products
  • Overview
  • Product Description
  • Application Field
  • One-stop Shopping
  • Certifications
  • Company Profile
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
UV-1100
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Can Be Customized Under Specific Situations
Product Name
UV- Visible Spectrophotometer
Band Width
4nm
Photometric Accuracy
±0.5% T
Photometric Repeatability
0.2% T
Wavelength Range
200~1000nm
Transport Package
Carton
Specification
460*330*210mm
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
1000PCS/Month

Packaging & Delivery

Package Size
60.00cm * 45.00cm * 32.00cm
Package Gross Weight
13.000kg

Product Description

 
Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
Product Description
Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
UV-1200 Uv/visible spectrophotometer series instruments, simple structure, stable and reliable, accurate reading, widely used in pharmaceutical, medical and health
Biotechnology, chemical industry, energy, machinery, metallurgy, environmental protection, geology, food, biology, materials, agriculture, forestry, fishery and other industries,Teaching and research in higher education, metrology and research institutes, as well as quality control in production, raw materials and Product inspection and other aspects play an important role, is commonly used in physical and chemical laboratory analysis instruments.

 

1. Large LCD screen (128x64 Dots).
2.Can display and save 50 groups of data, 3 groups per screen.
3.Data can be restored after a sudden power cut.
4.Auto setting wavelength.
5.Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime.
6.Automatical WL. calibration and dark current getting.
7.Optional Toption software UV-Professional can expand the applications to Kinetics and Quantitatives


Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer


 

Model
UV-1100
Optical System
Single beam, Grating 1200 lines/mm
Wavelength Range
200-1000nm
Bandwidth
4nm
Wavelength Accuracy
±2nm
Wavelength Repeatability
0.2nm
Wavelength Setting
Auto
Photometric Accuracy
±0.5%T
Photometric Repeatability
0.2%T
Photometric Range
-0.3-3A,0-200%T
Stray Light
≤0.3%T
Stability
± 0.001A/h @ 500nm
Display
128*64 Dots LCD
Detector
Silicon Photodiode
Standard Cell Holder
4-position 10mm cell changer
Light Source
Tungsten & Deuterium lamp
Output
USB Port & Parallel Port(Printer)
Power Requirements
AC 85~250V

Application Field

Application in water pollution monitoring

Water body eutrophication is the main condition of water body pollution. The content of ammonia scale in water exceeds the standard, resulting in further deterioration of water quality and environment. For the monitoring of water body pollution, it is necessary to start with two detection methods of amphos. (Ammonia mainly contains: nitrite, nitrateNitrogen, ammonia nitrogen, organic nitrogen, etc.; Phosphorus mainly contains soluble total phosphate, orthophosphoric acid Salt phosphorus, total phosphorus, etc. )
In addition, it can detect lignosulfonic acid, lignin, tannin, surfactant, fulvic acid, phenols, anilines, nitrophenolic compounds and other substances that are toxic to human body in tap water. Some tap water also contains total phenols, total aniline, nitrophenols and other substances that are toxic to human body, which also need to be detected by photometer.


 

One-stop Shopping

Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer

Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer

Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer

Certifications

Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer



 

Company Profile
Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.
Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometer
 
 
Exhibition

Macylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer ManufacturerMacylab-Factory Determination of Gold 4nm Stray Light Lower UV- Visible Spectrophotometer Manufacturer
FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier