• Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
  • Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
  • Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
  • Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
  • Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
  • Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry

Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry

After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Warranty: 1 Year
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry pictures & photos
Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
US $9,347 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Detailed Product Description
  • Main Features
  • Product Parameters
Overview

Basic Info.

Model NO.
UL2000
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Transport Package
Carton
Specification
360*
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
50PCS/Month

Packaging & Delivery

Package Size
31.00cm * 31.00cm * 31.00cm
Package Gross Weight
5.000kg

Product Description

Detailed Product Description

Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop SpectrophotometryLab Micro Volume with Minium Sample Size of 0.5UL Nanodrop SpectrophotometryLab Micro Volume with Minium Sample Size of 0.5UL Nanodrop SpectrophotometryLab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry

Minimum Sample Size: 0.5 Wavelength Range: 190-850nm
Optical Distance: 1mm/0.2mm/0.05mm Cuvette Optical Distance: 10mm/5mm/2mm/1mm
Wavelength Accuracy: 1nm Wavelength Resolution: ≤0.3nm(FWHM At Hg 253.7nm)
Absorbance Accuracy: 2%(0.76 At 257nm) Absorbance Resolution: 0.002Abs(at 1mm Optical Distance)
Absorbance Range: 0.005-300A(10mm Equivalent) Detection Range: Lower Limit 2ng/ul (dsDNA);Upper Limit 15000ng/ul (dsDNA)
Sample Pedestal Material: 304 Stainless Steal And Quartz Measurement Time: <5S
Detector: 3648CCD Light Source: Xenon Flash Lamp
Absorbance Test Range: 0.1~5Abs. ±0.1Abs 5~80Abs.±2% (can Extend To 300Abs) Dimensions (W X D X H)mm: 200*130*136
Weight: ≤2.5KG Operating Power: 24W
Voltage: AC100-240V;50-60Hz Display Language: English And Chinese
High Light:

macylab spectrophotometry lab

ul2000 spectrophotometry lab

uv / vis laboratory spectrophotometer

 
Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
 
UL-2000 Micro-Volume UV-V Spectrophotometer 

 Spectrophotometer is an important analysis instrument wildly applied in research of physics, chemistry, biology, medicine, material, enviroment and modern production management of chemistry, medicine, enviroment test, metallurgy. Spectrophotometer is the instrument for quantitative and quantitative analysis by spectrophotometry. It is usually used in quatitative research of nucleic acid, proteins and bacterial concentration.

Main Features

 

 *Microscale sample test, minium 0.5ul, ultromicro and cuvette are possible
*Wildly test area, 100 times of the traditional spectrophotometer
*No need to dilute for most samples
*Test directly, no need to warm-up, container test and daily consumtion test
*Whole wavelength 190-1100nm, accuracy 1nm, auto scannig wavelength 190-850nm
*Compact size and partable package fitable for on-site test
*More accurate and fexiable test is realized by PC contry
Product Parameters

 

Minimum Sample Size 0.5ul
Wavelength Range 190-850nm
Optical Distance 1mm/0.2mm/0.05mm
Cuvette Optical Distance 10mm/5mm/2mm/1mm
Wavelength Accuracy 1nm
Wavelength Resolution ≤0.3nm(FWHM at Hg 253.7nm)
Absorbance Accuracy 2%(0.76 at 257nm)
Absorbance Resolution 0.002Abs(at 1mm optical distance)
Absorbance Range 0.005-300A(10mm equivalent)
Detection Range Lower limit 2ng/ul (dsDNA);Upper limit 15000ng/ul (dsDNA)
Sample Pedestal Material 304 Stainless Steal and Quartz
Measurement Time <5S
Detector 3648CCD
Light Source Xenon flash lamp
Absorbance Test Range 0.1~5Abs. ±0.1Abs 5~80Abs.±2% (can extend to 300Abs)
Dimensions (W x D x H)mm 200*130*136
Weight ≤2.5KG
Operating Power 24W
Voltage AC100-240V;50-60Hz
Display Language

English and Chinese

 

Application Fields

 

Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry

 

Application Fields

Certificates


Application FieldsApplication Fields

Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry

 

Company Profile

 

Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry

 

Exhibitions
Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
 

 

Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry

 

                                                                                                                              Application Field                                                                                                                           Certificate                                                                                                      Company profile                                                                        

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry pictures & photos
Lab Micro Volume with Minium Sample Size of 0.5UL Nanodrop Spectrophotometry
US $9,347 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP