Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission

Product Details
Customization: Available
After-sales Service: 2years
Warranty: 1years
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission
  • Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission
  • Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission
  • Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission
  • Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission
  • Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission
Find Similar Products
  • Overview
  • One-stop Shopping
Overview

Basic Info.

Model NO.
ICP-6810
Analysis
Photoelectric Colorimetry
Display
Computer Screen
Application
Metal
Frequency
50±0.5Hz
Performance
Automation
Function
Storage, Cleared
Weight
100-500Kg
Power Source
AC220V±22V
Customized
Customized
Detector
Cid Detector
Power
800W-1500W
Wavelength Range
160-1000nm
Technical Parameter
RF Power
Transport Package
Carton
Specification
1800*800*850mm
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
5000PCS/Month

Packaging & Delivery

Package Size
150.00cm * 90.00cm * 108.00cm
Package Gross Weight
250.000kg

Product Description

Product description, technical parameters and configuration

Application Field
 
ICP-6810 is a full-spectrum direct-reading inductively coupled plasma emission spectrometer for the determination of trace and trace elements in different substances (dissolved in nitric acid, hydrochloric acid, hydrofluoric acid, etc.). It is widely used in environmental protection, petroleum products, rare earth, semiconductor, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.
Performance characteristics
Performance stability
The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.


Injection automation
Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.

Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical EmissionMacylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical EmissionMacylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical EmissionMacylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission
Precision analysis
The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.


Quick test
In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.
Technical parameters of the instrument
Output power: 800 -1500W

Total argon consumption:≤14L/min
Wavelength range:160nm - 1000 nm
Resolution: < 0.0065nm@200nm
Instrument technical index
Method of observation: vertical observation
Liquid content:0.01ppm~thousands of ppm.
Solid content:0.001%~70%
Repeatability: RSD < 1%
Stability: RSD <1.5%(within 2 hours)
Element detection limit (μg/L): most elements 1ppb~10ppb
Element WL(nm) Limit   Element WL(nm) Limit
La 408.672 <3.0   Cr 267.716 <5.0
Ce 413.765 <5.0   Al 396.152 <5.0
Pr 414.311 <5.0   Zr 343.823 <5.0
Nd 401.225 <5.0   Ag 328.068 <3.0
Sm 360.946 <10.0   Sr 407.771 <1.0
Eu 381.967 <1.0   Au 242.795 <5.0
Gd 342.247 <10.0   Pt 265.945 <5.0
Tb 350.917 <3.0   Pd 340.458 <5.0
Dy 353.170 <3.0   Ir 224.268 <10.0
Ho 345.600 <3.0   Rh 343.489 <10.0
Er 337.271 <3.0   Ru 240.272 <5.0
Tm 313.126 <3.0   Ba 455.403 <1.0
Yb 369.419 <1.0   As 228.812 ≤15
Lu 261.541 <3.0   Sb 206.833 ≤15
Y 371.030 <1.0   Bi 223.061 ≤10
Sc 335.373 <1.0   Hg 253.652 ≤15
Ta 226.230 <5.0   Pb 220.353 ≤15
Nb 313.340 <5.0   Ga 294.364 ≤10
Mn 257.610 <3.0   Se 203.985 ≤10
Mg 279.553 <1.0   Sn 242.949 ≤20
B 249.773 <10.0   Te 214.281 ≤10
Zn 213.856 <3.0   Ta 226.230 ≤5.0
Co 228.616 <3.0   Th 283.730 ≤10
Si 251.611 <10.0   Tl 276.787 ≤30
Ni 232.003 <5.0   Re 227.525 ≤5
Cd 226.502 <3.0   Ge 209.426 ≤15
Fe 239.562 <3.0   Os 225.585 ≤1
Ca 393.366 <1.0   W 207.911 ≤10
Mo 281.615 <5.0   Cu 324.754 <3.0
V 310.230 <5.0   Li 670.784 ≤3
Be 313.041 <1.0   Na 588.995 ≤20
Ti 334.941 <3.0   K 766.490 ≤60

Application area
Silicon industry, metallurgical industry, water quality analysis, geology, ore analysis, petrochemical, medical, sanitary, agricultural environmental protection, commodity, food quality inspection.
.
Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical EmissionMacylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission
One-stop Shopping

Macylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical EmissionMacylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical EmissionMacylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical EmissionMacylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical EmissionMacylab High Quality Cid&CCD Detector Inductively Coupled Plasma Optical Emission

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier