Mainframe
|
||
|
Model
|
:
|
AA-1800E
|
|
Light Source
|
:
|
≤8 lamps automatic turret, automatic alignment
|
|
Power Supply
|
:
|
110/220V (+5% ~ -10%), 60/50Hz; 5000VA
|
|
Lamp Current
|
:
|
pulsed power supply
|
|
Optical System
|
:
|
large 1800 /mm grating ruling, full closed optical system
|
|
Wavelength Range
|
:
|
190nm-900nm
|
|
Automatically peak find,a key opticaloptimization function
|
||
|
Wavelength Accuracy
|
:
|
≤0.15nm
|
|
Wavelength Repeatability
|
:
|
±0.1nm
|
|
Spectral Bandwidth
|
:
|
0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
|
|
(5 steps with automatic changeover)
|
||
|
Baseline Stability
|
:
|
≤±0.002A/30 min (Static)
|
|
≤±0.005A/30min (Dynamic)
|
||
|
Absorbance Range
|
:
|
0-4A
|
|
Flame Analytical System
|
||
|
Detector
|
:
|
imported photomultiplier tube
|
|
Burner Head
|
:
|
full titanium combustion head, 50mm or 100mm generalcombustion head
|
|
Atomization Chamber
|
:
|
polymer explosion-proof spray chamber
|
|
Nebulizer
|
:
|
atomizer efficient glass atomizer, can also be customized
|
|
Ignition Type
|
:
|
microcomputer control, automatic ignition
|
|
Gas Control
|
:
|
automatic gas control system
|
|
Detection Limits(Cu)
|
:
|
0.002μg/mL
|
|
Precision
|
:
|
RSD≤0.5%
|
|
Graphite Furnace Analytical System
|
||
|
Heating Mode
|
:
|
vertical heating
|
|
Temperature Control Method
|
:
|
vertical optical temperature monitoring graphite tube wall temperature
|
|
Temperature Range
|
:
|
room temperature to 3000ºC
|
|
The Program
|
:
|
automatic temperature control up to 20 order
|
|
Temperature Control
|
:
|
the furnace enriched up to 20 times
|
|
Characteristics Volume
|
:
|
0.5 × 10-12g (Cd)
|
|
Detection Limit
|
:
|
0.4 × 10-12g (Cd)
|
|
Precision
|
:
|
RSD≤3%
|
|
The Cooling Water
|
:
|
can choose cooling water circulation system
|
|
Safety
|
:
|
the graphite tube damage, water flow
|
|
air pressure and other alarmtemperature overheating protection
|
||
|
Autosampler Graphite Furnace
|
||
|
Sample Tray
|
:
|
70 sample cups, 6 reagent cup
|
|
Sample Volume
|
:
|
1-100μl
|
|
The Smallest Lincrement
|
:
|
0.1 μl
|
|
The Volume of Sample
|
:
|
better than 1%(at the time of 10mL-100mL)
|
|
Repeatability Volume
|
||
|
Repeated Sampling Frequency
|
:
|
up to 99 Times
|
|
Cleaning and Waste
|
:
|
each 500mL
|
Product Qualification: European safety qualification mark CE, North American safety certification ETL, Federal Communications Commission FCC, European electrical safety certification RoHS, China Quality Certification Center CQC, China national mandatory product certification 3C



| Drug analysis: | National Formulary" Available UV-visible spectrophotometry drugs for drug testing, drug analysis, pharmaceutical and other industries |
| Life Sciences: | DNA, protein concentration |
| Animal husbandry and fishery: | Pesticide residues, crop composition testing, veterinary testing, feed testing, fertilizer testing, soil composition testing, testing and other aquaculture |
| Metal elements: | Ag Cu Pb Zn Co Ni K Na Ca Mg Li Mn Cr As, including precious metals |
| Geological Survey: | Determination of metal elements in minerals and inorganic salts |
| Food safety: | Content of additives, preservatives, perfumes, fats, enzymes, sugars, spices, minerals, vitamins, etc. |
| Environmental monitoring: | Monitoring water, air, rainfall and soil, etc., in which the determination of various pollutants |

After carefully unpacking the contents, check the materials with the packing list (page 4) to ensure that you have received everything in good condition.
Place the instrument in a suitable location away from direct sunlight. In order to have the best performance from your instrument, keep it as far as possible from any strong magnetic or electrical fields or any electrical device that may generate high-frequency fields. Set the unit up in an area that is free of dust, corrosive gases and strong vibrations.
Remove any obstructions or materials that could hinder the flow of air under and around the instrument.
Use the appropriate power cord and plug into a grounded outlet.
Turn on your spectrophotometer. Allow it to warm up for 15 minutes before taking any readings. We suggest you then do the Calibrate System with the Search 656.1nm to set the wavelength to the deuterium lamp emission line.
Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.
Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.
Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.
Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry
Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.
Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.
Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.
Q8: Sample order is OK?
A8: Sample order is no problem.
Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.
Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.
Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.
Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.
Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.
Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.
Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS
Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.
Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.
Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.
Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.