Customization: | Available |
---|---|
After-sales Service: | Online Technical Support |
Application: | Laboratory Apparatus |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Shipping/Storage Ambient Temperatur: | 15ºC-25ºC | Atmospheric Pressure: | ≤70% |
---|---|---|---|
Power Supply: | 220±10V 50-60MHz | Working Humidity: | ≤70% |
Working Temperature: | Away From The Instrument, Electric Field: E<2V/m | Name: | ICP-6800 Inductively Coupled Plasma Optical Emission Spectrophotometer |
High Light: |
Inductively coupled plasma optical emission spectrophotometer,ICP -6800 inductively coupled plasma optical emission spectrophotometer |
ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard) |
Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.
Performance stability
The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient
Injection automation
The instrument is equipped with a four-channel twelve-roller high-precision peristaltic pump, which can guarantee the precision of injection and prevent liquid accumulation at the same time. The speed of the peristaltic pump can be adjusted continuously to meet various test requirements of customers.
Flow control parameters
Adopt imported high precision mass flow controller.
High precision constant temperature system
The whole optical path of adopt the precision constant temperature protection system. The temperature control can be set in real time according to the actual ambient temperature of the customer's laboratory, without the need to turn on the air conditioner continuously for a long time. Temperature control precision ≤±0.1%, precision constant temperature protection system to ensure the stability of the optical path and makes the test data more stable.
RFPower technical parameter
Circuit type |
solid-state RF Power supply, with function of automatch |
Frequercy |
27.12MHz±0.05% |
Frequency Stablity |
<0.1% |
Power Output |
800W-1200W |
Power Output Stability |
<0.3% |
Escaped RF radiation |
30cm away from the instrument, electric fiekd: E<2V/m |
Sampling System Technical Parameter
Output working coil imer diameter |
25mm |
Torpue tube |
Three concentric, extemal diameter 20mm |
Coaxial nebulizer |
Outer dameter 6mm |
Double barrel atomizing chamber |
Outer diameter 34mm |
Gas Flow Controls
Plasma Argon Flowmeter |
(100-1000)L/h(1.6-16L/min) |
Auxiliary Argon Fiowmeter |
(10-100)L/h(0.16-1.66L/min) |
Auxiliary Carrier Argon Flowmeter |
(10-100)L/h(0.16-1.66L/min) |
Pressune Maintaining Value |
(0-0.4MPa) |
Cooling Water:Temperature |
20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa |
Spectrometer
Optics |
Czerny-Turner type |
Focal length |
1000 mm |
Grating |
Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm |
Reciprocal linear dispersion |
0.26nm/mm |
Resolution |
≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating) |
Wavelength range |
3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm |
Minimum pace of stepping motor |
≤0.0006 nm |
Exit Slit |
12μm |
Entrance Slit |
10μm |
Photoelectric Converter Performance
Photomultiplier tube specification |
R293/R928 |
Negative HV on PMT |
0-1000V |
Stability |
<0.05% |
Overall Performance
Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)
Repeatability: RSD(Relative Standard Deviation)≤1.5%
Stability: RSD(Relative Standard Deviation) ≤2%
Detection Limits (µg/L):
Element | WL(nm) | Limit | Element | WL(nm) | Limit | |
La | 408.672 | <3.0 | Cr | 267.716 | <5.0 | |
Ce | 413.765 | <5.0 | Al | 396.152 | <5.0 | |
Pr | 414.311 | <5.0 | Zr | 343.823 | <5.0 | |
Nd | 401.225 | <5.0 | Ag | 328.068 | <3.0 | |
Sm | 360.946 | <10.0 | Sr | 407.771 | <1.0 | |
Eu | 381.967 | <1.0 | Au | 242.795 | <5.0 | |
Gd | 342.247 | <10.0 | Pt | 265.945 | <5.0 | |
Tb | 350.917 | <3.0 | Pd | 340.458 | <5.0 | |
Dy | 353.170 | <3.0 | Ir | 224.268 | <10.0 | |
Ho | 345.600 | <3.0 | Rh | 343.489 | <10.0 | |
Er | 337.271 | <3.0 | Ru | 240.272 | <5.0 | |
Tm | 313.126 | <3.0 | Ba | 455.403 | <1.0 | |
Yb | 369.419 | <1.0 | As | 228.812 | ≤15 | |
Lu | 261.541 | <3.0 | Sb | 206.833 | ≤15 | |
Y | 371.030 | <1.0 | Bi | 223.061 | ≤10 | |
Sc | 335.373 | <1.0 | Hg | 253.652 | ≤15 | |
Ta | 226.230 | <5.0 | Pb | 220.353 | ≤15 | |
Nb | 313.340 | <5.0 | Ga | 294.364 | ≤10 | |
Mn | 257.610 | <3.0 | Se | 203.985 | ≤10 | |
Mg | 279.553 | <1.0 | Sn | 242.949 | ≤20 | |
B | 249.773 | <10.0 | Te | 214.281 | ≤10 | |
Zn | 213.856 | <3.0 | Ta | 226.230 | ≤5.0 | |
Co | 228.616 | <3.0 | Th | 283.730 | ≤10 | |
Si | 251.611 | <10.0 | Tl | 276.787 | ≤30 | |
Ni | 232.003 | <5.0 | Re | 227.525 | ≤5 | |
Cd | 226.502 | <3.0 | Ge | 209.426 | ≤15 | |
Fe | 239.562 | <3.0 | Os | 225.585 | ≤1 | |
Ca | 393.366 | <1.0 | W | 207.911 | ≤10 | |
Mo | 281.615 | <5.0 | Cu | 324.754 | <3.0 | |
V | 310.230 | <5.0 | Li | 670.784 | ≤3 | |
Be | 313.041 | <1.0 | Na | 588.995 | ≤20 | |
Ti | 334.941 | <3.0 | K | 766.490 | ≤60 |
plication
Application Fields |
Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.
Application Fields
Certificates |
Application FieldsApplication Fields
Company Profile |
Exhibitions |
Application Field Certificate Company profile