Customization: | Available |
---|---|
After-sales Service: | Yes |
Application: | Industrial |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ICP-6800 Direct Reading Spectrometer ICP OES Emission Spectrometer ICP AES Atomic Emission Spectrometer
The ICP can measurate elements more than seventy that diversified from microanalysis to constant analysis. It is wide-ranging application in geologic,metallurgy, thulium, plating, cement,oil,chemical, environmental detection, coloured metal, physic sanitation, food, geoponics, scientific research, college and mine factory etc. It is not only good selling within the similar goods in our country but also have good reputation in international market.
It is the honesty that our company based on. Relying on the strong after-selling service system, our client can incisively use the instrument performance to the advantage, that can satisy the requirement of the quick and exact analysis performance of clients and avoid the trouble after selling.
Main characteristics:
1,The Self-sustaining radio frequency generator with power controlling makes the output power steady.
2,The design of the optimization optical reducing mottle light ,the high reticle ion etch holographic grating guarantee the high resolving power.
3,Adoptation of importation step motor and low modulus big-gear transmission framework guarantee scan precision.
4,Adoptation of intelligentize data transmission system heighten the analysis speed.
5,Adoptation of the Windows operating system of good operating system make the instrument operation convinient.
6,Adoptation of two grating for interconvert satisfy demanding of different users.
Software analysis way
1,Searching zero class
Searching zero class is instrument inspect orientation basic gist. The instrument auto zero class wave length revise and Confirm the instrument orientation zero before boot-strap every time.
2,Upbuild analysis way
After startup program, first according to the classification which is ready to be measured, user maybe take it from means interface element-circling period table and then choose that element chart line and relatively operation parameter. The user upbuild a suit of better analysis means which can greatly improve work efficiency.
3,Wave chart analysis
Adopt chart line that it has added in the means to process peak-searching task, the software can automaticly search chart line peak value, if the chart map has multipal peaks the user can choose it manuualy, that can get rid of disturbing element outside chart line.
4,Standard curve
The standard curve is the base of the quantified mearurement to sample products, commonly thing, should be choice high standard content and low standard content to upbuild a standard curve, the ready element content is the basis of this curve measure the intension to figure out the element concentration .
5,Sample measure
The sample measure is the basis of standard curve equation, search ready measure element photic intensity corresponding strength value, the corresponding strength value units may be use percent content % or ppm to show.
6,Data output
The measure result data can be seen or printed out in system.
Technique index
Sample introduction system
1,Quartz tubes: F20mm three concentric type
2,Nebulizer: F6mm coaxial type
3,Atomization chamber: F35mm double canister type
4,Plasma gas flow: 100-1000L/h
5,Assistant gas flow: 6-60L/h
6,Carrier gas volume: 6-60L/h
7,Carrier gas pressure: Maximum 0.3Mpa
Radio frequency generator
1,Circuit type: Self oscillate circuit,coaxial-cable output, matching tune
2,Work frequency: 40MHz
3,Frequency stability: <0.1%
4,Power output: 800-1200W
5,Power output stability: <0.2%
6,Power supply: 220V 25A
Scaning spectrophotometer
1,Light way system: Czerny Turner type
2,Focus: 750mm,1000mm
3,Grating: Ion etch holographic grating,
reticle density 3600line/mm&2400line/mm.
reticle area (80x100)mm
4,Resolving power: ≤0.008nm
5,Scan wavelength range: 3600line/mm scan wave length range:195 nm-500nm
2400line/mm scan wave length range:195nm-800nm
6,Scan step distance: 0.0006nm
7,Scan repeat quality: ≤0.0006nm
Inspection system
1,The F/V switch circuit controlled by singlechip
2,Sampling time: 100ms-10s
3,Photomultiplier Tube: R212UH
4,PMT negative high voltage: 200-990V, stability ≤0.05%
Equipment technical index:
1,Analytic speed: Over 10 element per minute
2,Precision: Relatively standard deviation RSD≤2%(short time stability)
3,Stability: Relatively standard deviation RSD≤3%(one hour measure)
4,Measure line range: ≥5 scalar class
5,Inspect lowest limit: Typical element inspect limit reference below table
Element | WL(nm) | Limit | Element | WL(nm) | Limit | |
La | 408.672 | <3.0 | Cr | 267.716 | <5.0 | |
Ce | 413.765 | <5.0 | Al | 396.152 | <5.0 | |
Pr | 414.311 | <5.0 | Zr | 343.823 | <5.0 | |
Nd | 401.225 | <5.0 | Ag | 328.068 | <3.0 | |
Sm | 360.946 | <10.0 | Sr | 407.771 | <1.0 | |
Eu | 381.967 | <1.0 | Au | 242.795 | <5.0 | |
Gd | 342.247 | <10.0 | Pt | 265.945 | <5.0 | |
Tb | 350.917 | <3.0 | Pd | 340.458 | <5.0 | |
Dy | 353.170 | <3.0 | Ir | 224.268 | <10.0 | |
Ho | 345.600 | <3.0 | Rh | 343.489 | <10.0 | |
Er | 337.271 | <3.0 | Ru | 240.272 | <5.0 | |
Tm | 313.126 | <3.0 | Ba | 455.403 | <1.0 | |
Yb | 369.419 | <1.0 | As | 228.812 | ≤15 | |
Lu | 261.541 | <3.0 | Sb | 206.833 | ≤15 | |
Y | 371.030 | <1.0 | Bi | 223.061 | ≤10 | |
Sc | 335.373 | <1.0 | Hg | 253.652 | ≤15 | |
Ta | 226.230 | <5.0 | Pb | 220.353 | ≤15 | |
Nb | 313.340 | <5.0 | Ga | 294.364 | ≤10 | |
Mn | 257.610 | <3.0 | Se | 203.985 | ≤10 | |
Mg | 279.553 | <1.0 | Sn | 242.949 | ≤20 | |
B | 249.773 | <10.0 | Te | 214.281 | ≤10 | |
Zn | 213.856 | <3.0 | Ta | 226.230 | ≤5.0 | |
Co | 228.616 | <3.0 | Th | 283.730 | ≤10 | |
Si | 251.611 | <10.0 | Tl | 276.787 | ≤30 | |
Ni | 232.003 | <5.0 | Re | 227.525 | ≤5 | |
Cd | 226.502 | <3.0 | Ge | 209.426 | ≤15 | |
Fe | 239.562 | <3.0 | Os | 225.585 | ≤1 | |
Ca | 393.366 | <1.0 | W | 207.911 | ≤10 | |
Mo | 281.615 | <5.0 | Cu | 324.754 | <3.0 | |
V | 310.230 | <5.0 | Li | 670.784 | ≤3 | |
Be | 313.041 | <1.0 | Na | 588.995 | ≤20 | |
Ti | 334.941 | <3.0 | K | 766.490 | ≤60 |
Q1: Why choose Macy Lab?
Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.
Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.
Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry
Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.
Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.
Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.
Q8: Sample order is OK?
A8: Sample order is no problem.
Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.
Q10: Can you offer quality certification?
A10: Of course. We have all kinds of certificate such as EU CE certification, EU ROHS certification, US FDA certification, CQO and ISO9001 Quality management system certification; environmental system certification ISO 14001; occupational health system certification ISO 45001; FCC certification and so on.
Q11: Are your operation keypad, interface, software and manual in English version?
A11: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.
Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.
Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.
Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.
Q15: How about OEM and ODM?
A16: More than 10 years experience in OEM and ODM.
Q16: What kinds of models do you make ?
A17: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS