• Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
  • Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
  • Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
  • Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
  • Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
  • Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer

Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer

After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Warranty: 1 Year
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer pictures & photos
Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
US $53,744 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Detailed Product Description
  • Main Features
  • Product Parameters
Overview

Basic Info.

Model NO.
ICP-6810
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Transport Package
Carton
Specification
360*
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
50PCS/Month

Packaging & Delivery

Package Size
150.00cm * 90.00cm * 106.00cm
Package Gross Weight
250.000kg

Product Description

Detailed Product Description

Determination of Oils Inductively Coupled Plasma Optical Emission SpectrometerDetermination of Oils Inductively Coupled Plasma Optical Emission SpectrometerDetermination of Oils Inductively Coupled Plasma Optical Emission SpectrometerDetermination of Oils Inductively Coupled Plasma Optical Emission Spectrometer

Name: Inductively Coupled Plasma Optical Emission Spectrometer Output Power: 800 -1500W
Total Argon Consumption: ≤14L/min Resolution: < 0.0065nm@200nm
Repeatability: RSD < 1% Stability: RSD <1.5%(within 2 Hours)
Wavelength Range: 160nm - 1000 Nm
 
Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
 
ICP-6810 Inductively Coupled Plasma Optical Emission Spectrometer

  ICP-6810 is a full-spectrum direct-reading inductively coupled plasma emission spectrometer for the determination of trace and trace elements in different substances (dissolved in nitric acid, hydrochloric acid, hydrofluoric acid, etc.).

    It is widely used in environmental protection, petroleum products, rare earth, semiconductor, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.

 

Main Features

 

 

Performance stability

The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.

 

Injection automation

Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.

 

Precision analysis

The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.

 

Quick test

In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.

 

Technical parameters of the instrument

  • Output power: 800 -1500W
  • Total argon consumption:≤14L/min
  • Wavelength range:160nm - 1000 nm
  • Resolution: < 0.0065nm@200nm

 

Instrument technical index

  • Method of observation: vertical observation
  • Liquid content:0.01ppm~thousands of ppm.
  • Solid content:0.001%~70%
  • Repeatability: RSD < 1%
  • Stability: RSD <1.5%(within 2 hours)
  • Element detection limit (μg/L): most elements 1ppb~10ppb
 
Product Parameters


 

RFPower technical parameter

ircuit type

solid-state RF Power supply, with function of automatch

Frequercy

27.12MHz±0.05%

Frequency Stablity

<0.1%

Power Output

800W-1500W

Power Output Stability

<0.3%

Escaped RF radiation

30cm away from the instrument, electric fiekd: E<2Vtm

 

Sampling System Technical Parameter

Output working coil imer diameter

25mm

Torpue tube

Three concentric, extemal diameter 20mm

Coaxial nebulizer

Outer dameter 6mm

Double barrel atomizing chamber

Outer diameter 34mm

 

Gas Flow Controls

Plasma Argon Flowmeter

(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter

(100-1000)L/h(0.16-1.6L/min)

Auxiliary Carrier Argon Flowmeter

(100-1000)L/h(0.16-1.6L/min)

Pressune Maintaining Value

(0-0.4MPa)

Cooling Water:Temperature

20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa

 

Technical index of spectrometer

Grating

Midde step grating, 52.67 lp/mm, 64 sparkle angle

Wavelength range

160-1000 nm

Numerical aperture

F≤8, ultra-high luminous flux to ensure the detection limit and sensitivity of the instrument

Resolution

< 0.0065nm@200nm

Astigmatism

Equivalent background concentration of 10000 ppm Ca solution at As 189.042 nm <2 ppm

Light chamber

Precision constant temperature, 35±0.1ºC, Distributed nitrogen punging, normal purging 1.8L/min, fast purging 3.8L/min

 

Testing device technical specifications

Detector

CID

Target Size

27.6mm x27.6mm, 1024x1024 addressing detection units

Reading mode

Non-destructive read (NDRO, full reading (FF) and arbitrary read integral (RAI)

 

 

Application Fields

 

Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer

 

Application Fields

Certificates


Application FieldsApplication Fields

Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer

 

Company Profile

 

Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer

 

Exhibitions
Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
 

 

Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer

 

                                                                                                                              Application Field                                                                                                                           Certificate                                                                                                      Company profile                                                                        

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer pictures & photos
Determination of Oils Inductively Coupled Plasma Optical Emission Spectrometer
US $53,744 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP