Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
  • Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
  • Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
  • Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
  • Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
  • Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
Find Similar Products
  • Overview
  • Product Description
  • One-stop Shopping
  • Application Field
  • Certifications
  • Company Profile
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
ICP-6800
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Product Name
Icp-6800
Shipping/Storage Ambient Temperature
15ºC-25ºC
Atmospheric Pressure
≤70%
Working Humidity
≤70%
Transport Package
Carton
Specification
360*
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
50PCS/Month

Packaging & Delivery

Package Size
180.00cm * 80.00cm * 85.00cm
Package Gross Weight
350.000kg

Product Description

Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software

Product Description
 
ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)

 

 Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.
 At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

 

Shipping/Storage Ambient Temperatur: 15ºC-25ºC Atmospheric Pressure: ≤70%
Power Supply: 220±10V 50-60MHz Working Humidity: ≤70%
Working Temperature: Away From The Instrument, Electric Field: E<2V/m Name: ICP-6800 Inductively Coupled Plasma Optical Emission Spectrophotometer
High Light:

inductively coupled plasma optical emission spectrophotometer

,
ICP

-6800 inductively coupled plasma optical emission spectrophotometer

 

Main features
Performance stability

The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.

 

Injection automation

The instrument is equipped with a four-channel twelve-roller high-precision peristaltic pump, which can guarantee the precision of injection and prevent liquid accumulation at the same time. The speed of the peristaltic pump can be adjusted continuously to meet various test requirements of customers.

 

Flow control parameters

Adopt imported high precision mass flow controller.

 

High precision constant temperature system

The whole optical path of adopt the precision constant temperature protection system. The temperature control can be set in real time according to the actual ambient temperature of the customer's laboratory, without the need to turn on the air conditioner continuously for a long time. Temperature control precision ≤±0.1%, precision constant temperature protection system to ensure the stability of the optical path and makes the test data more stable.
 

One-stop Shopping


Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software

Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven SoftwareIntellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven SoftwareIntellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven SoftwareIntellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software

 

RFPower technical parameter

 

Circuit type

solid-state RF Power supply, with function of automatch

Frequercy

27.12MHz±0.05%

Frequency Stablity

<0.1%

Power Output

800W-1200W

Power Output Stability

<0.3%

Escaped RF radiation

30cm away from the instrument, electric fiekd: E<2V/m


Sampling System Technical Parameter

 

Output working coil imer diameter

25mm

Torpue tube

Three concentric, extemal diameter 20mm

Coaxial nebulizer

Outer dameter 6mm

Double barrel atomizing chamber

Outer diameter 34mm

 

Gas Flow Controls

 

Plasma Argon Flowmeter

(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter

(10-100)L/h(0.16-1.66L/min)

Auxiliary Carrier Argon Flowmeter

(10-100)L/h(0.16-1.66L/min)

Pressune Maintaining Value

(0-0.4MPa)

Cooling Water:Temperature

20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa

 

Spectrometer

 

Optics

Czerny-Turner type

Focal length

1000 mm

Grating

Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion

0.26nm/mm

Resolution

≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating)

Wavelength range

3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm

Minimum pace of stepping motor

≤0.0006 nm

Exit Slit

12μm

Entrance Slit

10μm

 

Photoelectric Converter Performance

 

Photomultiplier tube specification

R293/R928

Negative HV on PMT

0-1000V

Stability

<0.05%


Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

 

Element WL(nm) Limit   Element WL(nm) Limit
La 408.672 <3.0   Cr 267.716 <5.0
Ce 413.765 <5.0   Al 396.152 <5.0
Pr 414.311 <5.0   Zr 343.823 <5.0
Nd 401.225 <5.0   Ag 328.068 <3.0
Sm 360.946 <10.0   Sr 407.771 <1.0
Eu 381.967 <1.0   Au 242.795 <5.0
Gd 342.247 <10.0   Pt 265.945 <5.0
Tb 350.917 <3.0   Pd 340.458 <5.0
Dy 353.170 <3.0   Ir 224.268 <10.0
Ho 345.600 <3.0   Rh 343.489 <10.0
Er 337.271 <3.0   Ru 240.272 <5.0
Tm 313.126 <3.0   Ba 455.403 <1.0
Yb 369.419 <1.0   As 228.812 ≤15
Lu 261.541 <3.0   Sb 206.833 ≤15
Y 371.030 <1.0   Bi 223.061 ≤10
Sc 335.373 <1.0   Hg 253.652 ≤15
Ta 226.230 <5.0   Pb 220.353 ≤15
Nb 313.340 <5.0   Ga 294.364 ≤10
Mn 257.610 <3.0   Se 203.985 ≤10
Mg 279.553 <1.0   Sn 242.949 ≤20
B 249.773 <10.0   Te 214.281 ≤10
Zn 213.856 <3.0   Ta 226.230 ≤5.0
Co 228.616 <3.0   Th 283.730 ≤10
Si 251.611 <10.0   Tl 276.787 ≤30
Ni 232.003 <5.0   Re 227.525 ≤5
Cd 226.502 <3.0   Ge 209.426 ≤15
Fe 239.562 <3.0   Os 225.585 ≤1
Ca 393.366 <1.0   W 207.911 ≤10
Mo 281.615 <5.0   Cu 324.754 <3.0
V 310.230 <5.0   Li 670.784 ≤3
Be 313.041 <1.0   Na 588.995 ≤20
Ti 334.941 <3.0   K 766.490 ≤60
Application Field

Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

 

Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software

 

Application Fields

Certifications

Aplication FieldsApplication Fields

Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software

 

Company Profile

 

Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
Shanghai Macylab Instrument Co., Ltd. is a high-tech enterprise with independent intellectual property rights, Macylab's entrepreneurial philosophy"
Technology -- change because of you",And take this as the mission of the company,Keep Keep exploring,Bold and innovative,Especially in the area of analytical test instruments,Constantly develop advanced products,Making Macylab a supplier and leader in quality instrument resources.
Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometer
Exhibition

 

Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
Intellectualized System Inductively Coupled Plasma Emission Spectrometer Ai-Driven Software
FAQ

 

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.

 

 

                                                                                                                              Application Field                                                                                                                           Certificate                                                                                                      Company profile                                                                        

 