Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis
  • Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis
  • Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis
  • Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis
  • Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis
  • Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Software features
  • One-stop Shopping
  • FAQ
Overview

Basic Info.

Model NO.
UV-1900PC
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Non-Customized
Product Name
UV Vis Spectrophotometer
Wavelength Range
190-900nm
Spectral Bandwidth
0.1,0.2,0.5,1.0,2.0,4.0nm
Wavelength Accuracy
0.3nm
Weight
28kg
Transport Package
Carton
Specification
560*450*230mm
Trademark
Macylab
Origin
Shanghai
HS Code
9027300090
Production Capacity
10000

Packaging & Delivery

Package Size
84.00cm * 65.00cm * 43.00cm
Package Gross Weight
33.000kg

Product Description

Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis

Product Description
Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis

UV-1900 dual-beam optical system, successfully achieved the perfect combination of high accuracy and reliability measurement to meet the requirements of various applications that can be used in biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical testing, health and epidemic prevention, and other fields.

A wide wavelength range, the wavelength range to meet the various requirements of the field

 

4nm, 2nm, 1nm, 0.5nm, 0.2nm, 0.1nm spectral bandwidth of the six countries to meet the stringent requirements of different users and pharmacopoeia

Automatic design to achieve the most simple means of measurement

LSI design greatly improves the scalability and reliability of the system

Improved optimization of the optical design, import source and receiver system created a high performance and high reliability

Rich measurement methods, with a wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination (optional), dual-wavelength, three- wavelength (optional) DNA protein measurements (optional), and other measurement methods to meet different measurement requirements, and can be displayed directly on a 6-inch screen

Based on user requirements optional hole rack, manual four with stand, manual Eighth rack, automatic Eighth frame, glass stand, test tube rack, 1cm colorimetric frame, 5cm colorimetric frame, 10cm colorimetric racks

Measurement data can be output through the printer with USB interface

Can be powered down to save the measurement parameters and data, user-friendly

Can achieve more accurate and flexible measurement via PC control, which can meet the needs of different users

Product Parameters

 

Optical System Double beam
Wavelength Range 190~1100nm
Band Width 0.1,0.2,0.5nm,1.0,2.0,4nm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability 0.1% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light ≤0.008% τ (220nm NaI,340nm NaNO2)
Stability 0.0005A/h@500nm
Noise ± 0.0002A @500nm
Baseline Flatness ± 0.001A
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -4~4A
Display Mode 6 inches high brightness blue LCD
Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 560×450×230mm
Weight 28Kg
 
Software features
 

Wavelength Scan: the measured object can be 190nm-1100nm full band spectrum scan , can also be segmented scan

Kinetic tests: the time of the measured object scanning , timely detection of changes in concentration caused by changes in absorbance

Quantitative measurement: by establishing a standard curve , the concentration can be measured in the analysis was

Multi- wavelength testing : set a plurality of wavelengths simultaneously , the measured absorbance of a plurality of wavelengths in the test

DNA / protein test: the test formula purity of nucleic acid and protein concentration analysis of DNA / protein


Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory AnalysisSpectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory AnalysisSpectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory AnalysisSpectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory AnalysisSpectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis
One-stop Shopping

 

Spectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory AnalysisSpectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory AnalysisSpectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory AnalysisSpectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory AnalysisSpectrophotometer From Macylab Double Beam Advanced UV Vis Spectrophotometer for Laboratory Analysis
FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.