Instrument adopts the analysis instrument independent research and development of all solid state radio frequency power supply, small volume, high efficiency, stable output power, with all kinds of protection function, and many other advantages, the load using automatic matching technology, matching speed, raise the use efficiency of the power and the stability of instruments, and makes the whole ignition process easy and convenient.
Sample injection automation
The four-channel automatic design is adopted, and the speed can be set and adjusted according to the test demand. The carrier gas, plasma gas and auxiliary gas are controlled by advanced mass flow controller. At the same time, it can be equipped with imported high-salt atomizer and imported hydrofluorine resistant atomizer, etc., to meet the various test needs of customers.
Accurate analysis
The medium step raster-prism cross dispersion method is adopted without moving optical elements. Ultra-low stray light design with unique optical design, nitrogen distributed blowing, imported optical components, intelligent and accurate automatic wavelength calibration algorithm.
High precision detector
Large size CID detector, wavelength range 165-900nm continuous coverage, one exposure, full spectrum display; Non-destructive reading (NDRO) function improves the signal to noise ratio of weak analysis line and the accuracy of results, and the data acquisition and analysis are better than CCD; The excellent linear dynamic range and inherent resistance to spillover ensure that lines of any strength can be measured and analyzed in a single exposure, while providing flexibility for the method to choose the ideal wavelength (second, third, or secondary sensitive lines can be selected to eliminate interference).
Super fast test speed
Each analysis spectrum line can be set any appropriate integration period in the exposure time to achieve the measurement optimization; The intensity integral value of all analytical spectral lines can be read out at one exposure to accelerate the analysis speed. Independent read-out of spectral lines can also be specified, with read-out time not exceeding 2ms.
Powerful software analysis function
The software is easy to operate and intuitive, with qualitative, semi-quantitative and quantitative analysis functions, instrument diagnosis and optimization functions, flexible full-spectrum research functions, powerful off-line reprocessing functions, scientific and intelligent background correction, interference removal algorithm functions, so that the test becomes more professional and accurate.
Instrument technical parameters
Technical specifications of RF generator
Input | 220VAC, 20A |
Output | 800 ~ 1500W |
Frequency stability | < 0.05% |
Output power stability | < 0.1% |
Leakage radiation intensity of electromagnetic field | Electric field intensity 30cm away from |
the chassis E | < 5V/m |
Technical index of injection device
Output working coil: inner diameter 25mm, 3 turns
Three concentric quartz torch: outer diameter 20mm; There are many models available according to the size of the center channel
Efficient imported atomizer: concentric atomizer, outer diameter 6mm; Multiple models optional, high salt, HF resistance, etc. '
Atomizing chamber: double cylinder atomizing chamber, can be selected swirl atomizing chamber, outer diameter 57.2mm
Peristaltic pump: twelve rotors and four channels, the speed can be adjusted according to the demand flow (that is, according to the injection speed setting, intuitive, accurate)
Total Argon consumption: Total argon consumption is less than 14L/min
Argon gas flowmeter and carrier gas pressure gauge specifications:
1. Plasma gas flowmeter (100~1000) L/h (1.6~16L/min)
2. Auxiliary gas flowmeter (6~60) L/h (0.1~1L/min)
3. Carrier gas flowmeter (6~60) L/h (0.1~1L/min)
4. Carrier gas regulator valve (0.2MPa)
5. Cooling water: water temperature 20~25ºC flow > 5 l/min hydraulic & gt; 0.1 MPa
Technical specifications of the beam splitter
Grating: Middle staircase grating, 52.67 lp/mm, 64 flare Angle, using German Schott thermal expansion coefficient close to zero
Zerodur material as the base, the performance is superior
Prism: ultra-pure Corning UV fused quartz, transmittance 99.6% at 170nm
The wavelength ranges from 165nm to 900nm
Focal length: 430 mm
Numerical aperture: F/8, ultra-high luminous flux to ensure the detection limit and sensitivity of the instrument
Resolution: < 0.0068 nm @ 200 nm
Stray light: equivalent background concentration of 10000ppmCa solution at As189.042nm < 2ppm
Optical chamber: precise constant temperature, 35±0.1ºC
Distributed nitrogen purge: 2L/min for normal purge and 4L/min for quick purge
Technical index of testing device
Detector Type: Charge Injection Detector (CID)
Target surface size: 27.6mm×27.6mm, 1024×1024 addressing detection unit
Read modes: Non-destructive Read (NDRO), Full-width Read (FF) and Arbitrary Read Integral (RAI)
Linear dynamic range: 108
Wavelength response range: 165nm to 1000nm
Electronic shutter: set the integration time of each spectral line separately; Independent read-out of spectral lines can be specified, read-out time < 2ms
Quantum efficiency: without any coating, the UV region of 200nm can reach more than 35%
Detector cooling: high efficiency three-stage semiconductor refrigeration, refrigeration temperature -45ºC
Instrument technical index
Observation method: vertical observation
Liquid content: 0.01ppm~ several thousand ppm
Solid content: 0.001%~70%
Repeatability: (i.e. short-term stability) relative standard deviation RSD< 1%
Stability: relative standard deviation RSD< 1.5% @ 2 hours
Test speed: The CID read-out time of a single spectral line is only 2ms, and all elements can be measured in one minute
Element detection limit (μg/L) : 1ppb to 10ppb for most elements
Application field
1. Silicon industry: magnetic material processing industry
2. Metallurgical industry: can analyze the quality of metal materials have a great impact on As, Bi, Pb, Sb, Sn and other impurities
3. Water quality analysis: eight heavy metals and other elements of water pollution can be detected
4. Geological and ore analysis: determination of Ca, Mg, Na, Fe, Cu, Mn, Zn, Co, Ni, Au, Ag and other elements in rock samples
5. Application in petrochemical and light industry fields: testing more than 30 elements in crude oil, mainly Fe, Na, Mg, Ni, V, Ca, Pb, Mo, Mn, Cr, Co, Ba, As, etc
6. Medical treatment, health, agricultural environmental protection, commodity, food quality test
Q1: Why choose Macy Lab?
Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.
Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.
Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry
Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.
Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.
Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.
Q8: Sample order is OK?
A8: Sample order is no problem.
Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.
Q10: Can you offer quality certification?
A10: Of course. We have all kinds of certificate such as EU CE certification, EU ROHS certification, US FDA certification, CQO and ISO9001 Quality management system certification; environmental system certification ISO 14001; occupational health system certification ISO 45001; FCC certification and so on.
Q11: Are your operation keypad, interface, software and manual in English version?
A11: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.
Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.
Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.
Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.
Q15: How about OEM and ODM?
A16: More than 10 years experience in OEM and ODM.
Q16: What kinds of models do you make ?
A17: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS