Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: <1year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
  • Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
  • Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
  • Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
  • Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
  • Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • One-stop Shopping
  • Certifications
  • Company Profile
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
AA-1800C
Display
LED
Appliance
Food Analysis, Medical Research, Biochemistry
Portable
Non Portable
Certification
RoHS, FCC, CE, ISO9001
Type
Conductivity Meter
Wavelength Range
190-900nm
Light Source
6 Hollow Cathode Lamps
Burning Head
All Titanium
Sample
Liquid
Transport Package
Carton
Specification
488mm*410mm*440mm
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
10000

Packaging & Delivery

Package Size
126.00cm * 64.00cm * 71.00cm
Package Gross Weight
120.000kg

Product Description

 

Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization

Product Description
Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
  AA-1800C atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.
  AA-1800 atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.

 

High precision automatic optical system
     1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 6 socket configuration six independent lamp power supply, can be respectively preheating
 
Polymer spray chamber
       Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability
 
Titanium burner
       Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame
 
Automatic analysis
       It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
      The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic
adjustment of the power supply parameters and the beam
position, automaticwavelength scanning and searching peak
 
Software function
       High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method
 
Product Parameters

 

                     Mainframe
Model
AA-1800C
Light Source
≤6 lamps automatic turret, automatic alignment
Power Supply
110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current
pulsed power supply
Optical System
large 1800 /mm grating ruling, full closed optical system
Wavelength Range
190nm-900nm                                                                                                 
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy
≤0.15nm
Wavelength Repeatability
±0.1nm
Spectral Bandwidth
0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
(5 steps with automatic changeover)
Baseline Stability
≤±0.002A/30 min (Static)     
≤±0.005A/30min (Dynamic)
Absorbance Range
0-4A
              Flame Analytical System
Detector
imported photomultiplier tube
Burner Head
full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber
polymer explosion-proof spray chamber
Nebulizer
atomizer efficient glass atomizer, can also be customized
Ignition Type
microcomputer control, automatic ignition
Gas Control
automatic gas control system
Detection Limits(Cu)
0.002μg/mL
Precision
RSD≤0.5%

 
Our Advantages

 

Quality
1. Our products have good quality and very positive reputations in the market. 
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders. 
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
One-stop Shopping

Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame AtomizationManufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame AtomizationManufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame AtomizationManufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame AtomizationManufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization

Certifications

 

Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
 
 
Company Profile

 

Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.
Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization
Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometer
Exhibition

Manufacture Low Price Lab Device Aas Atomic Absorbtion Spectrometer with Flame Atomization

FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.


 
Please Contact Us 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier