Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
  • Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
  • Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
  • Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
  • Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
  • Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
Find Similar Products

Basic Info.

Model NO.
AA-1800DL
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
Visible Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Transport Package
Carton
Specification
360*
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
50PCS/Month

Packaging & Delivery

Package Size
105.00cm * 70.00cm * 87.00cm
Package Gross Weight
129.000kg

Product Description

Product Description
AA-1800DL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.
AA-1800DL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.
 
Grating: 1800 /mm Wavelength Range: 190-900nm
Light Source: Aight Lamps Automatically Switch The Turret, Automatic Alignment

Images:
 
Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
Main Features
High precision automatic optical system
1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 8 socket configuration 8 independent lamp power supply, can be
respectively preheating
Polymer spray chamber
Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability
Titanium burner
Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame
Automatic analysis
It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic
adjustment of the power supply parameters and the beam
position, automaticwavelength scanning and searching peak
Software function
High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method

Product Parameters
Mainframe
Model : AA-1800DL
Light Source : ≤8 lamps automatic turret, automatic alignment
Power Supply : 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current : pulsed power supply
Optical System : large 1800 /mm grating ruling, full closed optical system
Wavelength Range : 185nm-900nm
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy : ±0.15nm
Wavelength Repeatability : <0.10nm
Spectral Bandwidth : 0.1,0.2,0.4,0.7,1.0,1.4,2.0nm
(7 steps with automatic changeover)
Baseline Stability : ≤±0.002A/30 min (Static)
≤±0.004A/30min (Dynamic)
Absorbance Range : 0-4A
Flame Analytical System
Detector : imported photomultiplier tube
Burner Head : full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber : polymer explosion-proof spray chamber
Nebulizer : atomizer efficient glass atomizer, can also be customized
Ignition Type : microcomputer control, automatic ignition
Gas Control : automatic gas control system
Detection Limits(Cu) : 0.002μg/mL
Precision : RSD≤0.5%

Our Advantages

 
FAQ
Q1. Are you a factory or a trading company?
We are a factory.
Q2. What's the MOQ ?
(1). Normally, MOQ is 1 piece. The quantity is depending on the clients' needs.
(2). If there is no stock, the general MOQ is in big difference due to the Different products. But the quantity still can be negotiated.
Q3. What is your principle for the samples ?
No free samples. But we provide 1piece as a sample order for all items.
Q4.Which payment can be acceptable ?
We could accept the payment by T/T, Paypal, Western Union,L/C, etc.
Q5. How about the lead time?
If no stocks, it takes 7 to 15 working days to manufacture after receiving the advance payment. If in stock, 2-4 working days are possible. But it depends on the exact products and quantity.
Q6. What certificates will be offered?
CE and ISO are certified for most products. Always high quality is offered to avoid any defective products. Also, protective packaging is offered to avoid destroy during delivery.
Q7. What language is offered?
Pure English for the operation panel, display and manuals. Installation & operation videos will be provided as a guidance if necessary.
Q8. What service do you provide after sales?
We could provide Online instructions: Real-time support by video-call or voice-chat. During the warranty time, we can send spare parts for free if any quality problems cause the products' inactive. Technical guidance is free and ready forever.
Q9. Can you give a training? Your technicians can come to our factory for a training. Drawell engineers can go to your place for local support( installation , training, debugging, maintenance ).
Q10. Can you do OEM? Products can be customized according to your requirements. OEM service is available

The Company

Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm


R&D

Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm

Our Factory 

Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm
 
 
                                                   Fully Automatic Collimation Atomic Absorption Spectrophotometer 185~900nm

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier