• AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer
  • AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer
  • AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer
  • AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer
  • AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer
  • AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer

AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer

After-sales Service: 1year
Warranty: 1year
Element: Organic Elemental Analyzer
Samples:
US$ 4301/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer pictures & photos
AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer
US $9,275 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • One-stop Shopping
  • Certifications
  • Exhibition
Overview

Basic Info.

Model NO.
AA-1800C
Analysis
Infrared Analysis
Display
Pointer
Application
Ceramics and Glass
Frequency
50±0.5Hz
Performance
Automation
Function
Storage, Cleared
Weight
100-500Kg
Power Source
AC220V±22V
Customized
Non-Customized
Transport Package
Carton
Specification
988*410*440mm
Trademark
Macy
Origin
China
HS Code
9027300090
Production Capacity
5000/PCS

Packaging & Delivery

Package Size
126.00cm * 64.00cm * 71.00cm
Package Gross Weight
120.000kg

Product Description

AA-1800C

Product description, technical parameters and configuration

    AA-1800C is a multifunctional atomic absorption spectrometer with two background correction methods, D lamp background elimination and self-absorption background deduction. It is a high precision analytical instrument integrates flame atomic absorption spectrometry (abbreviated as FAAS), and hydride generation atomic absorption spectrometry (abbreviated as HG-AAS), and atomic emission spectrometry (abbreviated as AES). An auto-sampler is optional to equip with graphite furnace atomic absorption spectrometry. AA-1800C is widely used in geology, metallurgy, mining, petroleum, chemical industry, mechanical, agriculture, food industry, medicine, health, antiepidemic, environmental protection, and other industries. And it is aessential high precision analytical instrument for scientific research institutes, colleges and universitiesand related enterprises.
 
                       

 

Main features
 
  • Advanced determination of flame atomic absorption spectrometry
It is developed by experienced professors and senior engineers who are engaged in analytical instrument industry of atomic absorption spectrometry for many years. The background correction with  hollow cathode lamp can eliminate the interference of molecular absorption in low content determination. The detection sensitivity is greatly improved, and the value is less than 0.015 μg/ml/1%.
  • High detection sensitivity and low detection limit of hydride generation atomic absorption spectrometry
The import known-how such as the advanced pneumatic component theory, and high performance hollow cathode lamp guarantees the hydride generation atomic absorption spectrometry performing a high detection sensitivity and low detection limit. For example, the detection sensitivity of Arsenic element is better than 0.08 ng/ml/1%The instrument precision is also greatly improved.
  • Convenient software operation system provides reliable data processing result
The data processing system of AA-1800C is an application of new data processing achievement in the field of atomic absorption spectrometry. It provides reliable data processing result. Meanwhile, the special designed operation software system is advanced and convenient.
  • Special designed double-loop power supply for the high performance hollow cathode lamp
AA-1800C uses special designed double-loop power supply for the high performance hollow cathode 
 
lamp, which is convenient for lamp adjusting. It not only improves the lamp energy of some element, but also improves the detection sensitivity to several times. And the performance indexes of the instrument such as stability and detection sensitivity are greatly improved.
  • Unique micro-volume sampler with constant current pulse
A unique micro-volume sampler with constant current pulse that designed based on the pneumatic component theory is optional to equip with flame atomic absorption spectrometry. The sample volume can be reduced to 0.1 ml, however, there is few influence on the detection sensitivity. And a relative standard deviation about of 1% can be obtained. Thus, it is very significant to medicine and health care industry.
  • Innovative detection system
Innovative atomic absorption detection system guarantees the instrument having an excellent stability. For a non-zeeman atomic absorption spectrometer, the detection precision of 0.0001A makes it to be unique.
  • USB communication port
The instrument is controlled by the USB port of computer, which is an advanced communication method. User can choose the computer as required, and that is also available for other laboratory use. However, to avoid viruses, please don't use this computer for internet surfing.
 
 
 
Technical parameters
Items Specifications  
Monochromator:    
Wavelength Rage: 190 nm ~900 nm  
Wavelength Accuracy: 0.15 nm  
Grating: 1800 lines/mm  
Optical System: C-T  
Blazed Wavelength: 250 nm  
Focal Length: 280 nm  
Reciprocal Linear Dispersion: 2 nm/mm  
Bandwidth: 1 mm / 0.2 mm / 0.05 mm, selectable  
Detection Sensitivity:    
FAAS: Cu: ≤0.05 μg/ml  
Detection Limit:    
FAAS: Cu: ≤0.008 μg/ml  
Measurement Repeatability(RSD):    
FAAS: Cu1%  
Stability (Baseline Drift):  0.005 A/30min  
Detection System:    
Photomultiplier (MPT): R928 / R955  
Negative High Voltage: 150 V ~ 800 V  
Gain: ×1×2, ×4  
Light Source:    
Lamps: HCL, HPHCL, Dz  
Lamp Position: No. 1 ~ No. 4: HCL  
  No. 5 , No. 6: HPHCL  
  Independent holder: Dz  
Lamp Current: HCL: 0.5 mA ~ 9.9 mA  
  HPHCL: 0.5 mA ~ 9.9 mA (main current), 
0.5 mA ~ 9.9 mA (auxiliary current)
 
  Dz: 0.5 mA ~ 19.9 mA  
Flame atomization System:    
Nebulizer: Glass nebulizer with metal sheath designed by Mr. Wu  
Burner: 100 mm Steel of Titanium alloy   
Flame Ignitor: Electronic pulse ignition  
Gas Flow Path:  Dual-channel designed, automatic security device with fuel gas flameout system 
 
Items Specifications  
Signal Processing:    
Signal Output: Total absorbance, net absorbance, background absorbance  
  Calculation methods: Average, peak height, peak area  
Readings: Absorbance: 0.001~2.000, 0.0001~2.0000, Concentration:0.001~9999  
  Calibration methods: 4 fitting methods, each curve up to 10 points  
  Statistics: SD, RSD, precision  
  Background correction methods: D lamp background elimination, self-absorption background deduction  
Dimensions:    
Main Structure: 988 mm× 412 mm× 440 mm (L×W×H)  
Power Supply of Graphite Furnace: 430 mm× 412 mm× 400 mm(L×W×H)  
Auto-sampler: 306 mm× 278 mm× 440 mm(L×W×H)  

AA1800c Six Lamp Single Flame Atomic Absorption SpectrophotometerAA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer

 
One-stop Shopping

AA1800c Six Lamp Single Flame Atomic Absorption SpectrophotometerAA1800c Six Lamp Single Flame Atomic Absorption SpectrophotometerAA1800c Six Lamp Single Flame Atomic Absorption SpectrophotometerAA1800c Six Lamp Single Flame Atomic Absorption SpectrophotometerAA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer

Certifications

AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer

Exhibition

AA1800c Six Lamp Single Flame Atomic Absorption SpectrophotometerAA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer pictures & photos
AA1800c Six Lamp Single Flame Atomic Absorption Spectrophotometer
US $9,275 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP