AA-1800C is a multifunctional atomic absorption spectrometer with two background correction methods, D lamp background elimination and self-absorption background deduction. It is a high precision analytical instrument integrates flame atomic absorption spectrometry (abbreviated as FAAS), and hydride generation atomic absorption spectrometry (abbreviated as HG-AAS), and atomic emission spectrometry (abbreviated as AES). An auto-sampler is optional to equip with graphite furnace atomic absorption spectrometry. AA-1800C is widely used in geology, metallurgy, mining, petroleum, chemical industry, mechanical, agriculture, food industry, medicine, health, antiepidemic, environmental protection, and other industries. And it is an essential high precision analytical instrument for scientific research institutes, colleges and universities, and related enterprises.
| Items | Specifications |
| Monochromator: | |
| Wavelength Rage: | 190 nm ~900 nm |
| Wavelength Accuracy: | ≤0.15 nm |
| Grating: | 1800 lines/mm |
| Optical System: | C-T |
| Blazed Wavelength: | 250 nm |
| Focal Length: | 280 nm |
| Reciprocal Linear Dispersion: | 2 nm/mm |
| Bandwidth: | 1 mm / 0.2 mm / 0.05 mm, selectable |
| Detection Sensitivity: | |
| FAAS: | Cu: ≤0.05 μg/ml |
| Detection Limit: | |
| FAAS: | Cu: ≤0.008 μg/ml |
| Measurement Repeatability(RSD): | |
| FAAS: | Cu: ≤1% |
| Stability (Baseline Drift): | ≤ 0.005 A/30min |
| Detection System: | |
| Photomultiplier (MPT): | R928 / R955 |
| Negative High Voltage: | 150 V ~ 800 V |
| Gain: | ×1, ×2, ×4 |
| Light Source: | |
| Lamps: | HCL, HPHCL, Dz |
| Lamp Position: | No. 1 ~ No. 4: HCL |
| No. 5 , No. 6: HPHCL | |
| Independent holder: Dz | |
| Lamp Current: | HCL: 0.5 mA ~ 9.9 mA |
| HPHCL: 0.5 mA ~ 9.9 mA (main current), 0.5 mA ~ 9.9 mA (auxiliary current) |
|
| Dz: 0.5 mA ~ 19.9 mA | |
| Flame atomization System: | |
| Nebulizer: | Glass nebulizer with metal sheath designed by Mr. Wu |
| Burner: | 100 mm Steel of Titanium alloy |
| Flame Ignitor: | Electronic pulse ignition |
| Gas Flow Path: | Dual-channel designed, automatic security device with fuel gas flameout system |
| Items | Specifications |
| Signal Processing: | |
| Signal Output: | Total absorbance, net absorbance, background absorbance |
| Calculation methods: | Average, peak height, peak area |
| Readings: | Absorbance: 0.001~2.000, 0.0001~2.0000, Concentration:0.001~9999 |
| Calibration methods: | 4 fitting methods, each curve up to 10 points |
| Statistics: | SD, RSD, precision |
| Background correction methods: | D lamp background elimination, self-absorption background deduction |
| Dimensions: | |
| Main Structure: | 988 mm× 412 mm× 440 mm (L×W×H) |
| Power Supply of Graphite Furnace: | 430 mm× 412 mm× 400 mm(L×W×H) |
| Auto-sampler: | 306 mm× 278 mm× 440 mm(L×W×H) |






Product Qualification: European safety qualification mark CE, North American safety certification ETL, Federal Communications Commission FCC, European electrical safety certification RoHS, China Quality Certification Center CQC, China national mandatory product certification 3C
After carefully unpacking the contents, check the materials with the packing list (page 4) to ensure that you have received everything in good condition.
Place the instrument in a suitable location away from direct sunlight. In order to have the best performance from your instrument, keep it as far as possible from any strong magnetic or electrical fields or any electrical device that may generate high-frequency fields. Set the unit up in an area that is free of dust, corrosive gases and strong vibrations.
Remove any obstructions or materials that could hinder the flow of air under and around the instrument.
Use the appropriate power cord and plug into a grounded outlet.
Turn on your spectrophotometer. Allow it to warm up for 15 minutes before taking any readings. We suggest you then do the Calibrate System with the Search 656.1nm to set the wavelength to the deuterium lamp emission line.
| Drug analysis: | National Formulary" Available UV-visible spectrophotometry drugs for drug testing, drug analysis, pharmaceutical and other industries |
| Life Sciences: | DNA, protein concentration |
| Animal husbandry and fishery: | Pesticide residues, crop composition testing, veterinary testing, feed testing, fertilizer testing, soil composition testing, testing and other aquaculture |
| Metal elements: | Ag Cu Pb Zn Co Ni K Na Ca Mg Li Mn Cr As, including precious metals |
| Geological Survey: | Determination of metal elements in minerals and inorganic salts |
| Food safety: | Content of additives, preservatives, perfumes, fats, enzymes, sugars, spices, minerals, vitamins, etc. |
| Environmental monitoring: | Monitoring water, air, rainfall and soil, etc., in which the determination of various pollutants |


Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.
Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.
Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.
Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry
Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.
Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.
Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.
Q8: Sample order is OK?
A8: Sample order is no problem.
Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.
Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.
Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.
Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.
Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.
Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.
Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS
Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.
Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.
Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.
Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.