• China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer
  • China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer
  • China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer
  • China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer
  • China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer
  • China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer

China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer

After-sales Service: 1year
Warranty: 1year
Element: Organic Elemental Analyzer
Samples:
US$ 4301/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer pictures & photos
China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer
US $9,275 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • One-stop Shopping
  • Certifications
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
AA-1800C
Analysis
Infrared Analysis
Display
Pointer
Application
Ceramics and Glass
Frequency
50±0.5Hz
Performance
Automation
Function
Storage, Cleared
Weight
100-500Kg
Power Source
AC220V±22V
Customized
Non-Customized
Wavelength Rage
190nm-900nm
Grating
1800lines/mm
Blazed Wavelength
250nm
Focal Length
280nm
Transport Package
Carton
Specification
988*410*440mm
Trademark
Macy
Origin
China
HS Code
9027300090
Production Capacity
5000/PCS

Packaging & Delivery

Package Size
126.00cm * 64.00cm * 71.00cm
Package Gross Weight
120.000kg

Product Description

China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer
Product Description

 

    AA-1800C is a multifunctional atomic absorption spectrometer with two background correction methods, D lamp background elimination and self-absorption background deduction. It is a high precision analytical instrument integrates flame atomic absorption spectrometry (abbreviated as FAAS), and hydride generation atomic absorption spectrometry (abbreviated as HG-AAS), and atomic emission spectrometry (abbreviated as AES). An auto-sampler is optional to equip with graphite furnace atomic absorption spectrometry. AA-1800C is widely used in geology, metallurgy, mining, petroleum, chemical industry, mechanical, agriculture, food industry, medicine, health, antiepidemic, environmental protection, and other industries. And it is aessential high precision analytical instrument for scientific research institutes, colleges and universitiesand related enterprises.
              
  • Advanced determination of flame atomic absorption spectrometry
It is developed by experienced professors and senior engineers who are engaged in analytical instrument industry of atomic absorption spectrometry for many years. The background correction with  hollow cathode lamp can eliminate the interference of molecular absorption in low content determination. The detection sensitivity is greatly improved, and the value is less than 0.015 μg/ml/1%.
  • High detection sensitivity and low detection limit of hydride generation atomic absorption spectrometry
The import known-how such as the advanced pneumatic component theory, and high performance hollow cathode lamp guarantees the hydride generation atomic absorption spectrometry performing a high detection sensitivity and low detection limit. For example, the detection sensitivity of Arsenic element is better than 0.08 ng/ml/1%The instrument precision is also greatly improved.
  • Convenient software operation system provides reliable data processing result
The data processing system of AA-1800C is an application of new data processing achievement in the field of atomic absorption spectrometry. It provides reliable data processing result. Meanwhile, the special designed operation software system is advanced and convenient.
  • Special designed double-loop power supply for the high performance hollow cathode lamp
AA-1800C uses special designed double-loop power supply for the high performance hollow cathode 
 
lamp, which is convenient for lamp adjusting. It not only improves the lamp energy of some element, but also improves the detection sensitivity to several times. And the performance indexes of the instrument such as stability and detection sensitivity are greatly improved.
  • Unique micro-volume sampler with constant current pulse
A unique micro-volume sampler with constant current pulse that designed based on the pneumatic component theory is optional to equip with flame atomic absorption spectrometry. The sample volume can be reduced to 0.1 ml, however, there is few influence on the detection sensitivity. And a relative standard deviation about of 1% can be obtained. Thus, it is very significant to medicine and health care industry.
  • Innovative detection system
Innovative atomic absorption detection system guarantees the instrument having an excellent stability. For a non-zeeman atomic absorption spectrometer, the detection precision of 0.0001A makes it to be unique.
  • USB communication port
The instrument is controlled by the USB port of computer, which is an advanced communication method. User can choose the computer as required, and that is also available for other laboratory use. However, to avoid viruses, please don't use this computer for internet surfing.
 
Product Parameters

 

Items Specifications
Monochromator:  
Wavelength Rage: 190 nm ~900 nm
Wavelength Accuracy: 0.15 nm
Grating: 1800 lines/mm
Optical System: C-T
Blazed Wavelength: 250 nm
Focal Length: 280 nm
Reciprocal Linear Dispersion: 2 nm/mm
Bandwidth: 1 mm / 0.2 mm / 0.05 mm, selectable
Detection Sensitivity:  
FAAS: Cu: ≤0.05 μg/ml
Detection Limit:  
FAAS: Cu: ≤0.008 μg/ml
Measurement Repeatability(RSD):  
FAAS: Cu1%
Stability (Baseline Drift):  0.005 A/30min
Detection System:  
Photomultiplier (MPT): R928 / R955
Negative High Voltage: 150 V ~ 800 V
Gain: ×1×2, ×4
Light Source:  
Lamps: HCL, HPHCL, Dz
Lamp Position: No. 1 ~ No. 4: HCL
  No. 5 , No. 6: HPHCL
  Independent holder: Dz
Lamp Current: HCL: 0.5 mA ~ 9.9 mA
  HPHCL: 0.5 mA ~ 9.9 mA (main current), 
0.5 mA ~ 9.9 mA (auxiliary current)
  Dz: 0.5 mA ~ 19.9 mA
Flame atomization System:  
Nebulizer: Glass nebulizer with metal sheath designed by Mr. Wu
Burner: 100 mm Steel of Titanium alloy 
Flame Ignitor: Electronic pulse ignition
Gas Flow Path:  Dual-channel designed, automatic security device with fuel gas flameout system 
Items Specifications
Signal Processing:  
Signal Output: Total absorbance, net absorbance, background absorbance
  Calculation methods: Average, peak height, peak area
Readings: Absorbance: 0.001~2.000, 0.0001~2.0000, Concentration:0.001~9999
  Calibration methods: 4 fitting methods, each curve up to 10 points
  Statistics: SD, RSD, precision
  Background correction methods: D lamp background elimination, self-absorption background deduction
Dimensions:  
Main Structure: 988 mm× 412 mm× 440 mm (L×W×H)
Power Supply of Graphite Furnace: 430 mm× 412 mm× 400 mm(L×W×H)
Auto-sampler: 306 mm× 278 mm× 440 mm(L×W×H)

China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas ManufacturerChina Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer

 
One-stop Shopping

China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas ManufacturerChina Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas ManufacturerChina Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas ManufacturerChina Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas ManufacturerChina Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer

Certifications

China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer

Exhibition

China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas ManufacturerChina Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer

FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer pictures & photos
China Factory Six Lamp Single Flame Atomic Absorption Spectrophotometer Aas Manufacturer
US $9,275 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP