• Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
  • Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
  • Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
  • Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
  • Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
  • Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer

Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer

After-sales Service: 2years
Warranty: 1years
Element: Metals Analyzer
Samples:
US$ 42000/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer pictures & photos
Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
US $42,000-55,500 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • One-stop Shopping
  • FAQ
Overview

Basic Info.

Model NO.
ICP6810
Analysis
Photoelectric Colorimetry
Display
Computer Screen
Application
Metal
Frequency
50±0.5Hz
Performance
Automation
Function
Storage, Cleared
Weight
100-500Kg
Power Source
AC220V±22V
Customized
Customized
Transport Package
Carton
Specification
1800*800*850mm
Trademark
Macylab
Origin
China
HS Code
9027300000
Production Capacity
5000PCS/Month

Packaging & Delivery

Package Size
180.00cm * 80.00cm * 85.00cm
Package Gross Weight
350.000kg

Product Description

Product description, technical parameters and configuration

Application Field
 
ICP-6800 is a full-spectrum direct-reading inductively coupled plasma emission spectrometer for the determination of trace and trace elements in different substances (dissolved in nitric acid, hydrochloric acid, hydrofluoric acid, etc.). It is widely used in environmental protection, petroleum products, rare earth, semiconductor, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.
Performance characteristics
Performance stability
The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.


Injection automation
Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.

Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission SpectrometerIcp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission SpectrometerIcp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission SpectrometerIcp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
Precision analysis
The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.


Quick test
In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.
Technical parameters of the instrument
Output power: 800 -1500W

Total argon consumption:≤14L/min
Wavelength range:160nm - 1000 nm
Resolution: < 0.0065nm@200nm
Instrument technical index
Method of observation: vertical observation
Liquid content:0.01ppm~thousands of ppm.
Solid content:0.001%~70%
Repeatability: RSD < 1%
Stability: RSD <1.5%(within 2 hours)
Element detection limit (μg/L): most elements 1ppb~10ppb

Application area

Silicon industry, metallurgical industry, water quality analysis, geology, ore analysis, petrochemical, medical, sanitary, agricultural environmental protection, commodity, food quality inspection.
 
Element WL(nm) Limit   Element WL(nm) Limit
La 408.672 <3.0   Cr 267.716 <5.0
Ce 413.765 <5.0   Al 396.152 <5.0
Pr 414.311 <5.0   Zr 343.823 <5.0
Nd 401.225 <5.0   Ag 328.068 <3.0
Sm 360.946 <10.0   Sr 407.771 <1.0
Eu 381.967 <1.0   Au 242.795 <5.0
Gd 342.247 <10.0   Pt 265.945 <5.0
Tb 350.917 <3.0   Pd 340.458 <5.0
Dy 353.170 <3.0   Ir 224.268 <10.0
Ho 345.600 <3.0   Rh 343.489 <10.0
Er 337.271 <3.0   Ru 240.272 <5.0
Tm 313.126 <3.0   Ba 455.403 <1.0
Yb 369.419 <1.0   As 228.812 ≤15
Lu 261.541 <3.0   Sb 206.833 ≤15
Y 371.030 <1.0   Bi 223.061 ≤10
Sc 335.373 <1.0   Hg 253.652 ≤15
Ta 226.230 <5.0   Pb 220.353 ≤15
Nb 313.340 <5.0   Ga 294.364 ≤10
Mn 257.610 <3.0   Se 203.985 ≤10
Mg 279.553 <1.0   Sn 242.949 ≤20
B 249.773 <10.0   Te 214.281 ≤10
Zn 213.856 <3.0   Ta 226.230 ≤5.0
Co 228.616 <3.0   Th 283.730 ≤10
Si 251.611 <10.0   Tl 276.787 ≤30
Ni 232.003 <5.0   Re 227.525 ≤5
Cd 226.502 <3.0   Ge 209.426 ≤15
Fe 239.562 <3.0   Os 225.585 ≤1
Ca 393.366 <1.0   W 207.911 ≤10
Mo 281.615 <5.0   Cu 324.754 <3.0
V 310.230 <5.0   Li 670.784 ≤3
Be 313.041 <1.0   Na 588.995 ≤20
Ti 334.941 <3.0   K 766.490 ≤60

Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission SpectrometerIcp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
One-stop Shopping

 

Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission SpectrometerIcp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission SpectrometerIcp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission SpectrometerIcp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission SpectrometerIcp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer pictures & photos
Icp6810 Determination of Gold Content in Rocks Inductively Coupled Plasma Emission Spectrometer
US $42,000-55,500 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP