Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: Online Technical Support
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
  • Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
  • Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
  • Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
  • Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
  • Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Product Application Scheme
  • One-stop Shopping
  • Certifications
  • Exhibition
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
AA-1800EL
Appliance
Food Analysis, Medical Research, Biochemistry
Portable
Non Portable
Certification
RoHS, FCC, CE, ISO9001
Type
Conductivity Meter
Wavelength Range
185-900nm
Wavelength Accuracy
0.15nm
Light Source
Six Lamps,Hollow Cathode Lamp
Optical System
Optical System
Transport Package
Carton
Specification
480× 350× 220mm
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
10000

Packaging & Delivery

Package Size
150.00cm * 75.00cm * 82.00cm
Package Gross Weight
223.000kg

Product Description

Product Description

 

Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
The eight lamp holder atomic absorption spectrometer is developed by using international new technology and experts from domestic universities. It has decades of experience in the development and application of spectroscopy instruments. The product includes flame, graphite furnace and hydride generation system, which can be equipped with a variety of accessories, and the flexible configuration scheme can meet the needs of customers at different levels. The fully automatic multifunctional atomic absorption spectrometer can perform complex sample analysis, and multiple analysis methods can be automatically switched to achieve unmanned automatic analysis.
 


Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab

 

Product Parameters
Mainframe
Model: AA-1800EL
Light Source: ≤ 8 lamps automatic turret, automatic alignment
Power Supply: 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current: pulsed power supply
Optical System: large 1800 /mm grating ruling, full closed optical system
Wavelength Range: 180nm-900nm                  
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy: ≤0.15nm
Wavelength Repeatability: ±0.1nm
Spectral Bandwidth: 0.1nm,0.2nm,0.4nm, 0.7nm,1.0nm,1.4nm,2.0nm
(7steps with automatic changeover)
Baseline Stability: ≤±0.002A/30 min (Static)      
≤±0.005A/30min (Dynamic)
Absorbance Range: 0-4A
Detector: imported photomultiplier tube 
Flame Analytical System
Burner Head: full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber: polymer explosion-proof spray chamber
Nebulizer: atomizer efficient glass atomizer, can also be customized
Ignition Type: microcomputer control, automatic ignition
Gas Control: automatic gas control system
Detection Limits(Cu): 0.002μg/mL
Precision: RSD≤0.5%
Graphite Furnace Analytical System
Heating Mode: vertical heating
Temperature Control Method: vertical optical temperature monitoring graphite tube wall temperature
Temperature Range: room temperature to 3000ºC
The Program: automatic temperature control up to 20 order
Temperature Control: the furnace enriched up to 20 times
Characteristics Volume: 0.5 × 10-12g (Cd)
Detection Limit: 0.4 × 10-12g (Cd)
Precision: RSD≤3%
The Cooling Water: can choose cooling water circulation system
Safety: the graphite tube damage, water flow
air pressure and other alarmtemperature overheating protection
Autosampler Graphite Furnace
Sample Tray: 70 sample cups, 6 reagent cup
Sample Volume: 1-100μl
The Smallest Lincrement: 0.1 μl
The Volume of Sample better than 1%(at the time of 10mL-100mL)
Repeatability Volume
Repeated Sampling Frequency: up to 99 Times
Cleaning and Waste each 500mL
Container Volume
Quality
1. Our products have good quality and very positive reputations in the market. 
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders. 
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Product Application Scheme

 

Application method of lead, cadmium and chromium in food(Graphite Furnace AAS)

Time:2022-11-14  Read: 47
Various limited metal components in food are determined under different spectral analysis with actual samples, in order to achieve the goal of comprehensive application of atomic absorption spectrometry. Select appropriate analysis conditions according to the analysis characteristics of each element, sample content, matrix composition and possible interference. It includes sample preparation, pretreatment, preparation of standard solution and preparation of calibration curve, selection of analysis conditions, operation method, result calculation, data processing and error analysis.

                  Standard basis: GB/T5009.12-2003/GB/T5009.15-2003/GB/T5009.123-2003/GB/T5009.123-2003 Determination of lead, cadmium and chromium in food
Theory
Graphite furnace automization is the most accurate and rapid method for the determination of harmful metal elements such as lead, cadmium and chromium in food. The detection limit of this method is 5u g/kg. It is a measurement method based on the light absorption of the ground state free atom at a specific wavelength. Its basic principle is to make the characteristic spectrum of the element to be measured radiated by the light source be absorbed by the ground state atom of the element to be measured in the steam when passing through the sample. Under a certain range and conditions, the degree of attenuation of the incident light absorbed is proportional to the content of the element to be measured in the sample, From this, the content of the elements to be measured in the sample can be obtained.
The ground state atoms of lead, cadmium, chromium and other elements in food selectively absorb the co radiation of the hollow cathode lamp, but the specific analysis conditions of each element are different. For example, the determination of lead is in an oxidizing atmosphere, but the determination of chromium requires a reducing atmosphere, and a high-performance hollow cathode lamp is required to obtain sufficient sensitivity. The sensitivity of these elements are different, so the concentration sequence is different when preparing the standard sequence, but they will not interfere with each other at a certain concentration, so their standard solutions can be mixed together for easy operation.
Instrument and Reductant
MACY AA-18800EL Graphite Furnace AAS Spectrophotometer (Background device with gas lamp buckle) and other parts ,like: Air cylinder;
Lead, cadmium, chromium and other elements hollow cathode lamp
Reference reagent: lead, cadmium and chromium standard stock solution. Matrix improvement reagent:
Ammonium phosphate solution (20g/L)
Hydrochloric acid solution(1mol/L)
Sodium citrate buffer solution (2mol/L)
Dithizone butyl acetate solution  (0.1%)
Sodium diethyldithiocarbamate solution (1%)
Standard solution of lead, cadmium and chromium series
Reagents for sample digestion and constant volume
microwave digestion
Get 0.2 g~0.8 g (accurate to 0.001 g) of solid sample or accurately move 0.500 ml~3.00 mL of liquid sample to microwave digestion oven , Add 5 ml. nitric acid, and digest the sample according to the operation steps of microwave digestion. Refer to Appendix A for digestion conditions. After cooling, take out the digestion tank, and flush the acid on the electric hot plate at 140 ºC~160 ºC to about 1 ml. After the digestion tank is cooled, transfer the digestion solution to a 10 ml volumetric flask, wash the digestion tank with a small amount of water for 2~3 times, combine the washing solution in the volumetric flask, and dilute it to the scale with water, then mix it well for standby. Conduct reagent blank test at the same time
User manual
1.Install the hollow cathode lamp of the element to be measured, align the position, and fix the wavelength to be measured and the slit width
2.Turn on the current and fix the lamp current.
3.Adjust the position of the graphite furnace to make it in the best condition, and install the graphite tube.
4.Turn on the cooling water and nitrogen gas sources and adjust them to the specified constant flow value.
5.Setting of determination parameters of each element (refer to Table 5-3-3 Flameless atomic absorption method for lead, cadmium and chromium)
Result
1.Standard curve
Make the standard solution, and then operate according to the sample oxidation and extraction methods. Take 10uL samples respectively, inject them into the graphite furnace, measure their absorbance values respectively, and obtain the linear regression equation of the relationship between the absorbance value and the concentration. (The absorbance of blank is deducted).
2.According to the absorbance of the sample and blank, substitute it into the linear regression equation of the standard series to obtain the content (ug) of a certain element (lead, cadmium, chromium) in the sample solution
Calculation formula
X =(A0-A1)/m
X--Content of certain element (lead, cadmium, chromium) in the sample mg/kg
A1--Weight of certain element (lead, pot, chromium) in the sample solution for determination g
A0--Weight of certain element (lead, pot, chromium) in reagent blank solution ,LG.,
m--Equivalent sample quality of sample test solution for determination, g.
 
One-stop Shopping

Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for LabAas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for LabAas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for LabAas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for LabAas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab

Certifications

 
Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
 
Exhibition

Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab

Company Profile
Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.
Aas Macylab AA-1800EL Flame Graphite Furnace Integrated Atomic Absorption Spectrometer for Lab
Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometer
FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.

 
Please Contact Us 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier