CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
After-sales Service: 1year
Warranty: 1year
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2012-02-21
Number of Employees
43
  • CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
  • CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
  • CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
  • CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
  • CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
  • CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
Find Similar Products
  • Overview
  • Our Advantages
  • Technical parameters
  • Packaging & Shipping
  • One-stop Shopping
  • Certifications
  • Application Field
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
AA-1800H
Element
Analytic Instrument for Trace Element
Analysis
Photoelectric Colorimetry
Display
Pointer
Application
Ceramics and Glass
Frequency
50±1HZ
Performance
Semi-automatic
Function
Cleared
Weight
0-100Kg
Power Source
AC220V±22V
Customized
Non-Customized
Wavelength Range
190-900nm
Atomizer
Efficient Glass Atomizer
Measurement Methods
Flame and Hydride Method
Relative Humidity
20-80%
Transport Package
Put Into Into Sea
Specification
988*412*440nm
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
5000/PCS

Packaging & Delivery

Package Size
126.00cm * 64.00cm * 71.00cm
Package Gross Weight
120.000kg

Product Description

CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
AA-1800H is a multifunctional atomic absorption spectrometer with two background correction methods, D lamp background elimination and self-absorption background deduction. It is a high precision analytical instrument integrates flame atomic absorption spectrometry (abbreviated as FAAS), and hydride generation atomic absorption spectrometry (abbreviated as HG-AAS), and graphite furnace atomic absorption spectrometry (abbreviated as GFAAS), and atomic emission spectrometry (abbreviated as AES). An auto-sampler is optional to equip with graphite furnace atomic absorption spectrometry. AA-1800H is widely used in geology, metallurgy, mining, petroleum, chemical industry, mechanical, agriculture, food industry, medicine, health, antiepidemic, environmental protection, and other industries. And it is an essential high precision analytical instrument for scientific research institutes, colleges and universities, and related enterprises.

AA-1800H can be used for analyzing metallic elements, amphoteric elements, and alkali elements. It's a high precision analytical instrument with high performance and its determination range can be from ppb to ppt

CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
                      
Our Advantages
  • Advanced determination of flame atomic absorption spectrometry
It is developed by experienced professors and senior engineers who are engaged in analytical instrument industry of atomic absorption spectrometry for many years. The background correction with Deuterium hollow cathode lamp can eliminate the interference of molecular absorption in low content determination. The detection sensitivity is greatly improved, and the value is less than 0.015 μg/ml/1%.
  • High detection sensitivity and low detection limit of hydride generation atomic absorption spectrometry
The import known-how such as the advanced pneumatic component theory, and high performance hollow cathode lamp guarantees the hydride generation atomic absorption spectrometry performing a high detection sensitivity and low detection limit. For example, the detection sensitivity of Arsenic element is better than 0.08 ng/ml/1%. The instrument precision is also greatly improved.
  • Convenient software operation system provides reliable data processing result
The data processing system of AA-1800H is an application of new data processing achievement in the field of atomic absorption spectrometry. It provides reliable data processing result. Meanwhile, the special designed operation software system is advanced and convenient.
  • A partly substitution of graphite furnace atomic spectrometry
The atomic absorption spectrometry together with on-line enrichment by the pneumatic flow injection system designed by ourselves can determine some elements and obtain a high sensitivity, that means it is a partly substitution of graphite furnace atomic spectrometry for certain elements. Thus, it not only reduces the testing cost, but also improves the instrument utilization.
  • Special designed double-loop power supply for the high performance hollow cathode lamp
AA-1800H uses special designed double-loop power supply for the high performance hollow cathode lamp, which is convenient for lamp adjusting. It not only improves the lamp energy of some element, but also improves the detection sensitivity to several times. And the performance indexes of the instrument such as stability and detection sensitivity are greatly improved.
  • Unique micro-volume sampler with constant current pulse
A unique micro-volume sampler with constant current pulse that designed based on the pneumatic component theory is optional to equip with flame atomic absorption spectrometry. The sample volume can be reduced to 0.1 ml, however, there is few influence on the detection sensitivity. And a relative standard deviation about of 1% can be obtained. Thus, it is very significant to medicine and health care industry.
  • Innovative detection system
Innovative atomic absorption detection system guarantees the instrument having an excellent stability. For a non-zeeman atomic absorption spectrometer, the detection precision of 0.0001A makes it to be unique.
  • USB communication port
The instrument is controlled by the USB port of computer, which is an advanced communication method. User can choose the computer as required, and that is also available for other laboratory use. However, to avoid viruses, please don't use this computer for internet surfing.

 
Technical parameters
Items Specifications
Monochromator:  
Wavelength Rage: 190 nm ~900 nm
Wavelength Accuracy: 0.15 nm
Grating: 1800 lines/mm
Optical System: C-T
Blazed Wavelength: 250 nm
Focal Length: 280 nm
Reciprocal Linear Dispersion: 2 nm/mm
Bandwidth: 1 mm / 0.2 mm / 0.05 mm, selectable
Detection Sensitivity:  
FAAS: Cu: ≤0.05 μg/ml
GFAAS: Cd: ≤1 pg, Cu: ≤80 pg
Detection Limit:  
FAAS: Cu: ≤0.008 μg/ml
GFAAS:  
Measurement Repeatability(RSD):  
FAAS: Cu: 1%
GFAAS: Cd: ≤5%, Cu: ≤4%
Stability (Baseline Drift):  0.005 A/30min
Detection System:  
Photomultiplier (MPT): R928 / R955
Negative High Voltage: 150 V ~ 800 V
Gain: ×1, ×2, ×4
Light Source:  
Lamps: HCL, HPHCL, Dz
Lamp Position: No. 1 ~ No. 4: HCL
  No. 5 , No. 6: HPHCL
  Independent holder: Dz
Lamp Current: HCL: 0.5 mA ~ 9.9 mA
  HPHCL: 0.5 mA ~ 9.9 mA (main current),
0.5 mA ~ 9.9 mA (auxiliary current)
  Dz: 0.5 mA ~ 19.9 mA
Flame atomization System:  
Nebulizer: Glass nebulizer with metal sheath designed by Mr. Wu
Burner: 100 mm Steel of Titanium alloy
Flame Ignitor: Electronic pulse ignition
Gas Flow Path: Dual-channel designed, automatic security device with fuel gas flameout system
 


 

Items
Specifications
Graphite furnace atomization System:  
Temperature control range: Room temperature ~ 3000ºC
Programmed temperature control: Up to 20 stages, ramp and step heating
Drying stage: Up to 8 stages, each 4 stages for ramp and step heating, each stage 0~99 s duration time
Ashing stage: Up to 8 stages, each 4 stages for ramp and step heating, each stage 0~99 s duration time
Atomization stage: Ramp and step heating, 0~20 s duration time
Clear stage: Ramp and step heating, 0~20 s duration time
Heating mode: High power heating, and optically controlled high power heating with the temperature range of 1500ºC~3000ºC, with graphite tube temperature self calibration function
Temperature accuracy: ≤1%
Heating rate: ≥2000 ºC/s
Security arrangement: Cooling water flow: ≤0.75 L/min (Cooling water supply: ≥0.75 L/min)
  Alarm, and automatically stop heating program when following situation occurs: argon pressure <0.3 MPa, or cooling water temperature ≥60ºC
  Heating program is not allowed when bad contact of graphite tube occurs
  Over current protection
  With the graphite tube usage recording function to remind users to replace the graphite tube when it reaching its service life
Gas control: Internal gas: 0~300 ml/min, with the internal of 20 ml/min
  External gas: 0, or 1.5 L/min (The external gas is supplied with certain flow of during the four heating stages of drying, ashing, atomization and clear, and there are three kinds of cooling times for chosen, 15 s, 30 s, 45 s. Besides, the external gas is shut off)
Graphite tube type: Ordinary, pyrogenic and platform graphite tubes
Graphite tube fixing: Pneumatic switch controlled by computer, stable and safe, with good contact.
Signal Processing:  
Signal Output: Total absorbance, net absorbance, background absorbance
  Calculation methods: Average, peak height, peak area
Readings: Absorbance: 0.001~2.000, 0.0001~2.0000, Concentration:0.001~9999
  Calibration methods: 4 fitting methods, each curve up to 10 points
  Statistics: SD, RSD, precision
  Background correction methods: D lamp background elimination, self-absorption background deduction
Dimensions:  
Main Structure: 988 mm× 412 mm× 440 mm (L×W×H)
Power Supply of Graphite Furnace: 430 mm× 412 mm× 400 mm(L×W×H)
Auto-sampler: 306 mm× 278 mm× 440 mm(L×W×H)

Packaging & Shipping

After carefully unpacking the contents, check the materials with the packing list (page 4) to ensure that you have received everything in good condition.

Place the instrument in a suitable location away from direct sunlight.  In order to have the best performance from your instrument, keep it as far as possible from any strong magnetic or electrical fields or any electrical device that may generate high-frequency fields. Set the unit up in an area that is free of dust, corrosive gases and strong vibrations.

Remove any obstructions or materials that could hinder the flow of air under and around the instrument.

Use the appropriate power cord and plug into a grounded outlet.

Turn on your spectrophotometer. Allow it to warm up for 15 minutes before taking any readings. We suggest you then do the Calibrate System with the Search 656.1nm to set the wavelength to the deuterium lamp emission line.

 

CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
 
One-stop Shopping

CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption SpectrophotometerCE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer
CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption SpectrophotometerCE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer

Certifications

Product Qualification: European safety qualification mark CE, North American safety certification ETL, Federal Communications Commission FCC, European electrical safety certification RoHS, China Quality Certification Center CQC, China national mandatory product certification 3C

CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer

Application Field
Drug analysis: National Formulary" Available UV-visible spectrophotometry drugs for drug testing, drug analysis, pharmaceutical and other industries
Life Sciences: DNA, protein concentration
Animal husbandry and fishery: Pesticide residues, crop composition testing, veterinary testing, feed testing, fertilizer testing, soil composition testing, testing and other aquaculture
Metal elements: Ag Cu Pb Zn Co Ni K Na Ca Mg Li Mn Cr As, including precious metals
Geological Survey: Determination of metal elements in minerals and inorganic salts
Food safety: Content of additives, preservatives, perfumes, fats, enzymes, sugars, spices, minerals, vitamins, etc.
Environmental monitoring: Monitoring water, air, rainfall and soil, etc., in which the determination of various pollutants

CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer

 

Exhibition

CE Certificate Brand Factory Macylab Flame Graphite Furnace System Atomic Absorption Spectrophotometer

FAQ

1. How to pick up the best among these models?
A:Tell us your request on product and almost target price,we recommend you the most suitable model. Selling you the most expensive product is not our goal,selling you the most suitable is!


2. How to place order or pay?
you can place order to us directly,we offer you PI (contract) with bank information, you pay here,we ship the product,Every process is based on PI.


3. How to transport the product?
A: Depending on the quantity and what kind of machine you order or whether you are urgent or not to check how big it is to check the freight.
By sea: More than 60kg or big quantity;Safe,cheap but slow;
Usually 11-30 days to North America;
30-45 days to Middle of South America;
40-60 days to South America;
15-28 days to South Africa;
25-33 days to Europe;
30-45 days to East Europe;
35-45 days to North Europe;
28-35 days to Mediterranean countries;
28-40 days to Middle East countries;
7-20 days to Southeast Asia countries;
By air to airport: Suit for big product or quantity but urgent a lot. Usually 7-10 days arrive. Some direct flight can arrive at 3-5 days.
By Express delivery such as DHL,FedEx,TNT: Suit for small or not too heavy and very urgent product. Generally 5-7 days arrive.

4. What kind of warranty will be offer?
A: Most of our product we offer 1 years warranty,except perishable part. During the warranty time,any problem,we offer after-sale service;  Welcome our customer talk this with our sales directly,they will offer you more details;


5. How's our service?
A: Before place order,any inquiry we make sure will reply in 1 day,and offer you our suitable advice based on our professional product knowledge;
After place order,we will help you follow the shipping information until you get these machines;
If any problems on delivery or using,we make sure you can contact us in 1 day. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now