Customization: | Available |
---|---|
After-sales Service: | 1year |
Warranty: | 1year |
Still deciding? Get samples of US$ 16000/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items | Specifications | |
Monochromator: | ||
Wavelength Rage: | 190 nm ~900 nm | |
Wavelength Accuracy: | ≤0.15 nm | |
Grating: | 1800 lines/mm | |
Optical System: | C-T | |
Blazed Wavelength: | 250 nm | |
Focal Length: | 280 nm | |
Reciprocal Linear Dispersion: | 2 nm/mm | |
Bandwidth: | 1 mm / 0.2 mm / 0.05 mm, selectable | |
Detection Sensitivity: | ||
FAAS: | Cu: ≤0.05 μg/ml | |
GFAAS: | Cd: ≤1 pg, Cu: ≤80 pg | |
Detection Limit: | ||
FAAS: | Cu: ≤0.008 μg/ml | |
GFAAS: | ||
Measurement Repeatability(RSD): | ||
FAAS: | Cu: ≤1% | |
GFAAS: | Cd: ≤5%, Cu: ≤4% | |
Stability (Baseline Drift): | ≤ 0.005 A/30min | |
Detection System: | ||
Photomultiplier (MPT): | R928 / R955 | |
Negative High Voltage: | 150 V ~ 800 V | |
Gain: | ×1, ×2, ×4 | |
Light Source: | ||
Lamps: | HCL, HPHCL, Dz | |
Lamp Position: | No. 1 ~ No. 4: HCL | |
No. 5 , No. 6: HPHCL | ||
Independent holder: Dz | ||
Lamp Current: | HCL: 0.5 mA ~ 9.9 mA | |
HPHCL: 0.5 mA ~ 9.9 mA (main current), 0.5 mA ~ 9.9 mA (auxiliary current) |
||
Dz: 0.5 mA ~ 19.9 mA | ||
Flame atomization System: | ||
Nebulizer: | Glass nebulizer with metal sheath designed by Mr. Wu | |
Burner: | 100 mm Steel of Titanium alloy | |
Flame Ignitor: | Electronic pulse ignition | |
Gas Flow Path: | Dual-channel designed, automatic security device with fuel gas flameout system |
Items |
Specifications | |
Graphite furnace atomization System: | ||
Temperature control range: | Room temperature ~ 3000ºC | |
Programmed temperature control: | Up to 20 stages, ramp and step heating | |
Drying stage: | Up to 8 stages, each 4 stages for ramp and step heating, each stage 0~99 s duration time | |
Ashing stage: | Up to 8 stages, each 4 stages for ramp and step heating, each stage 0~99 s duration time | |
Atomization stage: | Ramp and step heating, 0~20 s duration time | |
Clear stage: | Ramp and step heating, 0~20 s duration time | |
Heating mode: | High power heating, and optically controlled high power heating with the temperature range of 1500ºC~3000ºC, with graphite tube temperature self calibration function | |
Temperature accuracy: | ≤1% | |
Heating rate: | ≥2000 ºC/s | |
Security arrangement: | Cooling water flow: ≤0.75 L/min (Cooling water supply: ≥0.75 L/min) | |
Alarm, and automatically stop heating program when following situation occurs: argon pressure <0.3 MPa, or cooling water temperature ≥60ºC | ||
Heating program is not allowed when bad contact of graphite tube occurs | ||
Over current protection | ||
With the graphite tube usage recording function to remind users to replace the graphite tube when it reaching its service life | ||
Gas control: | Internal gas: 0~300 ml/min, with the internal of 20 ml/min | |
External gas: 0, or 1.5 L/min (The external gas is supplied with certain flow of during the four heating stages of drying, ashing, atomization and clear, and there are three kinds of cooling times for chosen, 15 s, 30 s, 45 s. Besides, the external gas is shut off) | ||
Graphite tube type: | Ordinary, pyrogenic and platform graphite tubes | |
Graphite tube fixing: | Pneumatic switch controlled by computer, stable and safe, with good contact. | |
Signal Processing: | ||
Signal Output: | Total absorbance, net absorbance, background absorbance | |
Calculation methods: | Average, peak height, peak area | |
Readings: | Absorbance: 0.001~2.000, 0.0001~2.0000, Concentration:0.001~9999 | |
Calibration methods: | 4 fitting methods, each curve up to 10 points | |
Statistics: | SD, RSD, precision | |
Background correction methods: | D lamp background elimination, self-absorption background deduction | |
Dimensions: | ||
Main Structure: | 988 mm× 412 mm× 440 mm (L×W×H) | |
Power Supply of Graphite Furnace: | 430 mm× 412 mm× 400 mm(L×W×H) | |
Auto-sampler: | 306 mm× 278 mm× 440 mm(L×W×H) |