• Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
  • Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
  • Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
  • Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
  • Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
  • Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h

Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h

After-sales Service: 1year
Warranty: 1year
Element: Analytic Instrument for Trace Element
Samples:
US$ 16000/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h pictures & photos
Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
US $13,188 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • One-stop Shopping
Overview

Basic Info.

Model NO.
AA-1800H
Analysis
Photoelectric Colorimetry
Display
Pointer
Application
Ceramics and Glass
Frequency
50±1HZ
Performance
Semi-automatic
Function
Cleared
Weight
0-100Kg
Power Source
AC220V±22V
Customized
Non-Customized
Transport Package
Put Into Into Sea
Specification
988*412*440nm
Trademark
Macylab
Origin
China
HS Code
9027300090
Production Capacity
5000/PCS

Packaging & Delivery

Package Size
126.00cm * 64.00cm * 71.00cm
Package Gross Weight
120.000kg

Product Description


 
Product Brief Introduction

AA-1800H is a multifunctional atomic absorption spectrometer with two background correction methods, D lamp background elimination and self-absorption background deduction. It is a high precision analytical instrument integrates flame atomic absorption spectrometry (abbreviated as FAAS), and hydride generation atomic absorption spectrometry (abbreviated as HG-AAS), and graphite furnace atomic absorption spectrometry (abbreviated as GFAAS), and atomic emission spectrometry (abbreviated as AES). An auto-sampler is optional to equip with graphite furnace atomic absorption spectrometry. AA-1800H is widely used in geology, metallurgy, mining, petroleum, chemical industry, mechanical, agriculture, food industry, medicine, health, antiepidemic, environmental protection, and other industries. And it is an essential high precision analytical instrument for scientific research institutes, colleges and universities, and related enterprises.

AA-1800H can be used for analyzing metallic elements, amphoteric elements, and alkali elements. It's a high precision analytical instrument with high performance and its determination range can be from ppb to ppt
 
                       

 

Main features
 
  • Advanced determination of flame atomic absorption spectrometry
It is developed by experienced professors and senior engineers who are engaged in analytical instrument industry of atomic absorption spectrometry for many years. The background correction with Deuterium hollow cathode lamp can eliminate the interference of molecular absorption in low content determination. The detection sensitivity is greatly improved, and the value is less than 0.015 μg/ml/1%.
  • High detection sensitivity and low detection limit of hydride generation atomic absorption spectrometry
The import known-how such as the advanced pneumatic component theory, and high performance hollow cathode lamp guarantees the hydride generation atomic absorption spectrometry performing a high detection sensitivity and low detection limit. For example, the detection sensitivity of Arsenic element is better than 0.08 ng/ml/1%. The instrument precision is also greatly improved.
  • Convenient software operation system provides reliable data processing result
The data processing system of AA-1800H is an application of new data processing achievement in the field of atomic absorption spectrometry. It provides reliable data processing result. Meanwhile, the special designed operation software system is advanced and convenient.
  • A partly substitution of graphite furnace atomic spectrometry
The atomic absorption spectrometry together with on-line enrichment by the pneumatic flow injection system designed by ourselves can determine some elements and obtain a high sensitivity, that means it is a partly substitution of graphite furnace atomic spectrometry for certain elements. Thus, it not only reduces the testing cost, but also improves the instrument utilization.
  • Special designed double-loop power supply for the high performance hollow cathode lamp
AA-1800H uses special designed double-loop power supply for the high performance hollow cathode lamp, which is convenient for lamp adjusting. It not only improves the lamp energy of some element, but also improves the detection sensitivity to several times. And the performance indexes of the instrument such as stability and detection sensitivity are greatly improved.
  • Unique micro-volume sampler with constant current pulse
A unique micro-volume sampler with constant current pulse that designed based on the pneumatic component theory is optional to equip with flame atomic absorption spectrometry. The sample volume can be reduced to 0.1 ml, however, there is few influence on the detection sensitivity. And a relative standard deviation about of 1% can be obtained. Thus, it is very significant to medicine and health care industry.
  • Innovative detection system
Innovative atomic absorption detection system guarantees the instrument having an excellent stability. For a non-zeeman atomic absorption spectrometer, the detection precision of 0.0001A makes it to be unique.
  • USB communication port
The instrument is controlled by the USB port of computer, which is an advanced communication method. User can choose the computer as required, and that is also available for other laboratory use. However, to avoid viruses, please don't use this computer for internet surfing.
 
 
Instrument Specifications
 
Items Specifications  
Monochromator:    
Wavelength Rage: 190 nm ~900 nm  
Wavelength Accuracy: 0.15 nm  
Grating: 1800 lines/mm  
Optical System: C-T  
Blazed Wavelength: 250 nm  
Focal Length: 280 nm  
Reciprocal Linear Dispersion: 2 nm/mm  
Bandwidth: 1 mm / 0.2 mm / 0.05 mm, selectable  
Detection Sensitivity:    
FAAS: Cu: ≤0.05 μg/ml  
GFAAS: Cd: ≤1 pg, Cu: ≤80 pg  
Detection Limit:    
FAAS: Cu: ≤0.008 μg/ml  
GFAAS:    
Measurement Repeatability(RSD):    
FAAS: Cu: 1%  
GFAAS: Cd: ≤5%, Cu: ≤4%  
Stability (Baseline Drift):  0.005 A/30min  
Detection System:    
Photomultiplier (MPT): R928 / R955  
Negative High Voltage: 150 V ~ 800 V  
Gain: ×1, ×2, ×4  
Light Source:    
Lamps: HCL, HPHCL, Dz  
Lamp Position: No. 1 ~ No. 4: HCL  
  No. 5 , No. 6: HPHCL  
  Independent holder: Dz  
Lamp Current: HCL: 0.5 mA ~ 9.9 mA  
  HPHCL: 0.5 mA ~ 9.9 mA (main current),
0.5 mA ~ 9.9 mA (auxiliary current)
 
  Dz: 0.5 mA ~ 19.9 mA  
Flame atomization System:    
Nebulizer: Glass nebulizer with metal sheath designed by Mr. Wu  
Burner: 100 mm Steel of Titanium alloy  
Flame Ignitor: Electronic pulse ignition  
Gas Flow Path: Dual-channel designed, automatic security device with fuel gas flameout system  

Items
Specifications  
Graphite furnace atomization System:    
Temperature control range: Room temperature ~ 3000ºC  
Programmed temperature control: Up to 20 stages, ramp and step heating  
Drying stage: Up to 8 stages, each 4 stages for ramp and step heating, each stage 0~99 s duration time  
Ashing stage: Up to 8 stages, each 4 stages for ramp and step heating, each stage 0~99 s duration time  
Atomization stage: Ramp and step heating, 0~20 s duration time  
Clear stage: Ramp and step heating, 0~20 s duration time  
Heating mode: High power heating, and optically controlled high power heating with the temperature range of 1500ºC~3000ºC, with graphite tube temperature self calibration function  
Temperature accuracy: ≤1%  
Heating rate: ≥2000 ºC/s  
Security arrangement: Cooling water flow: ≤0.75 L/min (Cooling water supply: ≥0.75 L/min)  
  Alarm, and automatically stop heating program when following situation occurs: argon pressure <0.3 MPa, or cooling water temperature ≥60ºC  
  Heating program is not allowed when bad contact of graphite tube occurs  
  Over current protection  
  With the graphite tube usage recording function to remind users to replace the graphite tube when it reaching its service life  
Gas control: Internal gas: 0~300 ml/min, with the internal of 20 ml/min  
  External gas: 0, or 1.5 L/min (The external gas is supplied with certain flow of during the four heating stages of drying, ashing, atomization and clear, and there are three kinds of cooling times for chosen, 15 s, 30 s, 45 s. Besides, the external gas is shut off)  
Graphite tube type: Ordinary, pyrogenic and platform graphite tubes  
Graphite tube fixing: Pneumatic switch controlled by computer, stable and safe, with good contact.  
Signal Processing:    
Signal Output: Total absorbance, net absorbance, background absorbance  
  Calculation methods: Average, peak height, peak area  
Readings: Absorbance: 0.001~2.000, 0.0001~2.0000, Concentration:0.001~9999  
  Calibration methods: 4 fitting methods, each curve up to 10 points  
  Statistics: SD, RSD, precision  
  Background correction methods: D lamp background elimination, self-absorption background deduction  
Dimensions:    
Main Structure: 988 mm× 412 mm× 440 mm (L×W×H)  
Power Supply of Graphite Furnace: 430 mm× 412 mm× 400 mm(L×W×H)  
Auto-sampler: 306 mm× 278 mm× 440 mm(L×W×H)  






Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
One-stop Shopping

Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800hSingle Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h pictures & photos
Single Flame Atomic Absorption Spectrometerinteregrated with Graphite Furnace AA-1800h
US $13,188 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP