Chemical Cosmetic Flame Atomic Absorption Spectrometry Hollow cathode lamps
Specifications:
Mainframe | |
Model: | AA-1800H |
Light Source: | ≤6 lamps automatic turret, automatic alignment |
Power Supply: | 110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
Lamp Current: | pulsed power supply |
Optical System: | large 1800 /mm grating ruling, full closed optical system |
Wavelength Range: | 180nm-900nm |
Automatically peak find,a key opticaloptimization function | |
Wavelength Accuracy: | ≤0.15nm |
Wavelength Repeatability: | ±0.1nm |
Spectral Bandwidth: | 0.1nm,0.2nm,0.4nm,1.0nm,2.0nm |
(5 steps with automatic changeover) | |
Baseline Stability: | ≤±0.002A/30 min (Static) |
≤±0.005A/30min (Dynamic) | |
Absorbance Range: | 0-4A |
Detector: | imported photomultiplier tube |
Flame Analytical System | |
Burner Head: | full titanium combustion head, 50mm or 100mm generalcombustion head |
Atomization Chamber: | polymer explosion-proof spray chamber |
Nebulizer: | atomizer efficient glass atomizer, can also be customized |
Ignition Type: | microcomputer control, automatic ignition |
Gas Control: | automatic gas control system |
Detection Limits(Cu): | 0.002μg/mL |
Precision: | RSD≤0.5% |
Graphite Furnace Analytical System | |
Heating Mode: | vertical heating |
Temperature Control Method: | vertical optical temperature monitoring graphite tube wall temperature |
Temperature Range: | room temperature to 3000ºC |
The Program: | automatic temperature control up to 20 order |
Temperature Control: | the furnace enriched up to 20 times |
Characteristics Volume: | 0.5 × 10-12g (Cd) |
Detection Limit: | 0.4 × 10-12g (Cd) |
Precision: | RSD≤3% |
The Cooling Water: | can choose cooling water circulation system |
Safety: | the graphite tube damage, water flow |
air pressure and other alarmtemperature overheating protection | |
Autosampler Graphite Furnace | |
Sample Tray: | 70 sample cups, 6 reagent cup |
Sample Volume: | 1-100μl |
The Smallest Lincrement: | 0.1 μl |
The Volume of Sample | better than 1%(at the time of 10mL-100mL) |
Repeatability Volume | |
Repeated Sampling Frequency: | up to 99 Times |
Cleaning and Waste | each 500mL |
Container Volume |
Photos: