Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP
  • Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
  • Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
  • Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
  • Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
  • Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
  • Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Certifications
  • Company Profile
  • Exhibition
  • One-stop Shoping
  • FAQ
Overview

Basic Info.

Model NO.
AA-1800DL
Warranty
1 Year
Detection Method
Spectrograph
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
Infrared Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Wavelength Range
185-900nm
Wavelength Accuracy
±0.15nm
Wavelength Repeatability
<0.1nm
Spectral Bandwidth
0.1, 0.2, 0.4, 0.7, 1.0, 1.4, 2.0nm
Transport Package
Carton
Specification
eight lamp
Trademark
Macylab
Origin
Jiangsu
HS Code
9027300090
Production Capacity
5000

Packaging & Delivery

Package Size
150.00cm * 75.00cm * 82.00cm
Package Gross Weight
223.000kg

Product Description

     
Product Description

 

Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
AA-1800DL atomic absorption spectrometer is developed by using new international technology and experts from domestic universities. It has decades of experience in the development and application of spectral instruments. The products include flame, graphite furnace and hydride generation system, can be configured with a variety of accessories, flexible configuration solutions to meet the needs of different levels of customers. Fully automatic multifunctional AA-1800EL atomic absorption spectrometer can carry out complex sample analysis, and a variety of analysis methods can be switched automatically, so as to achieve unmanned automatic analysis
Product Parameters

 

Model AA-1800DL
Wavelength Range 185-900nm
Wavelength Accuracy ±0.15nm
Wavelength Repeatability <0.1nm
Spectral bandwidth 0.1,0.2,0.4,0.7,1.0,1.4,2.0nm   Automatic seventh-gear switch
Flame system
Combustion head All-titanium burner, 50mm or 100mm universal burner
Gas control Japan imported mass flowmeter,Automatic microcomputer control system
Characteristic concentration(Cu) <0.15ug/ml/1%
Detection limit(Cu) <0.002ug/ml
Precision(Cu) <0.5%
Piping module The machine adopts sealed stainless steel pipeline inside, without replacement for life, to avoid the aging phenomenon of plastic pipeline
Security Gas leakage alarm, anti-backfire automatic protection, abnormal automatic power off and other protective measures
 
Our Advantages


1, Double layer cast aluminum plate structure, cast aluminum structure optical path (optical element fasteners base 20mm cast aluminum plate), most manufacturers on the market for sheet metal structure, cast aluminum structure for a long time high temperature use is not easy to deformation, and good heat dissipation, to a large extent to ensure the stability of the optical path structure (good stability), long distance transportation or bumpy its optical path structure is not easy to change;

2, The instrument graphite furnace method of light temperature control directly monitoring the temperature of the inner wall of the graphite tube, closer to the sample, making the temperature rise more smooth and stable, other companies are basically testing the outer wall of the graphite tube, the value of the inner wall detection is more accurate and effective, and more suitable to test the sample, the sample detection is more accurate;

3, Wavelength precision screw drive, for four subdivision drive, step can be accurate to 0.005nm, other basic no subdivision, step is 0.02nm, is four times of other companies, greatly increasing the accuracy and repeatability of the instrument wavelength;

4. The spectrum slit adopts the etching process, which is more accurate than the traditional manual stitching, and the thickness is only 0.07mm, effectively avoiding diffraction;

5, Deuterium lamp buckle background this piece, with deuterium hollow cathode lamp and other companies use deuterium arc lamp, deuterium hollow cathode lamp long service life, and not easy to heat, but deuterium arc lamp low cost, short service life, and easy to heat, easy to damage

6, Detection limit: according to the sensitivity of different elements, the detection limit of each element is different, the higher the sensitivity, the lower the detection limit, copper: 0.002ug/ml, cadmium: 0.0002ug /ml

7, The application technology of hydride method is mature, the instrument test can be repeated two to three times, take the average, the same industry can only read once, including imported instruments;

8, The classic graphite furnace circuit, the first in China, using KCB472 thyristor trigger transformer structure design, fully enclosed printed circuit board directly welding installation;

9, Abnormal automatic alarm, automatic shutdown system, automatic power off can save the measurement data, the internal use of stainless steel pipeline, to avoid the aging phenomenon of plastic pipeline.

 
Certifications

 

Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
 
Company Profile

 

Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometer
 
Exhibition

 

Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
 
One-stop Shoping

 

Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
Determination of Tin From Stationary Sources in The Atmosphere Atomic Absorption Spectrometer
 
FAQ

 

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier